background image

9

Mareli Systems

The main frame shows: 

time and date, chrono activation, combustion 

power and recipe, functioning state, error code, 

main temperature, main thermostat, 

summer/winter mode.

Button 

Function 

P1 

P2 

P3 

P4 

P5

 

P6

 

Exit Menu/Submenu;
Ignition and extinguishing (push for 3 seconds), Reset errors (push for 3 seconds), Enable/disable chrono;
Enter in User Menu 1/submenu, Enter in User Menu 2 (push for 3 seconds), Save data;
Enter in Visualizations Menu, Increase
Activation chrono time band
Enter in Visualizations Menu, Decrease

Led

 

Function 

D1 

D9 

D2 

D10 

D3 

D11 

D5 

D12 

Auger ON

V2:

 Pump 1 ON

R: 

Igniter ON 

Aux2: 

Pump 2 ON

 

External Chrono reached

Lack of pellet

Local Room Thermostat reached

Sanitary water demand

Er01 

- Security Error High Voltage 1. It may also intervene with the system off;

Er02 

- Security Error High Voltage 2. It can only intervene if the Combustion fan is active;

Er03 

- Extinguishing for low exhaust temperature or missing light in the brazier;

Er04 

- Extinguishing for water over temperature;

Er05 

- Extinguishing due to high exhaust temperature;

Er06 

- Pellet Thermostat open (flame return from the brazier);

Er07 

- Encoder Error. The error may occur due to lack signal from Encoder;

Er08 

- Encoder Error. The error can occur due to problems of adjustment of the number of revolutions;

Er09 

- Water pressure low;

Er10 

- Water pressure high;

Er11 

- Clock Error. The error occurs due to problems with the internal clock;

Er12 

- Extinguishing for ignition failure;

Er15 

- Extinguishing due to power failure for more than 50 minutes;

Er16 

- RS485 communication error (Display);

Er17 

- Adjusting the Air Flow Failed;

Er18 

- No more Pellet in the bunker;

Er23 

- Boiler probe or Back boiler probe or probe Buffer open;

Er25 

- Engine cleaning brazier broken;

Er26 

- Engine cleaning broken;

Er27 

- Engine cleaning 2 broken;

Er34 

- Depression below the minimum threshold;

Er35 

- Depression above the maximum threshold;

Er39 

- Sensor Flowmeter broken;

Er41 

- Minimum air flow in Check Up is not reached;

Er42 

- Maximum air flow exceeded;

Er44 

- Open door error;

Er47 

- Error Encoder Auger: missing signal Encoder;

Er48 

- Error Encoder Auger: Auger regulation speed not achieved;

Er52 

- Error Module I/O I2C; 

Er57 

- Test ’Forced Draught High’ in Check Up fail ;

Service 

- Service error. It notifies that the planned hours of functioning is reached. It is necessary to call for service.

ALARMS

CONTROL PANEL: USE AND FUNCTIONS

Summary of Contents for CBM 45

Page 1: ...Pellet Water Boiler CBM 45 Assembly and exploitation manual Mareli Systems...

Page 2: ...ion and exploitation manual of the pellet bunker if the device is provided with one The non fulfillment of prescriptions and violation of active regulations and directives may lead to damage and unexp...

Page 3: ...ed service technician to establish whether the equipment is safe There is a risk of thermostat damage and melting the flexible pellet feeding tube To prevent backfire it should be checked if the burne...

Page 4: ...oiler needs to be well levelled thus ensuring its proper venting Attention Fire risk due to flammable materials and liquids Make sure no flammable materials and or liquids are in the vicinity of the h...

Page 5: ...pressure of the water must be equal to 2 bar the maximum to 6 0 bar There must be an available capacity of at least 11 l min Connect the safety heat exchanger according to the hydraulic chart with a...

Page 6: ...installation for user Attention Hazard to life in case of non observation of the safety prescriptions Functions of Individual Elements Strong fanning can lead to flame extinguishing due to excessive...

Page 7: ...a temperature of around 90 is reached Remove the tar from the floor and the heating surfaces by the cleaning spade Boiler Inspection and Maintenance Why is regular maintenance important These are the...

Page 8: ...an be monitored on the display Warranty The manufacturer guarantees correct and reliable operation of the product only when requirements for in stallation and operation are met according to the manual...

Page 9: ...tat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to problems of adjustment of the number of revo...

Page 10: ...ond case the user selects the desired power On the left side of the display are signalled the combustion modality A automatic combustion M manual combustion and the working power of the system Recipe...

Page 11: ...day at the desired time Ex 6 30 The system turns on at 20 30 on Tuesday and turns off at 6 30 on Wednesday Weekly The programs are the same for all days of the week Week end Choose between Monday Fri...

Page 12: ...12 Mareli Systems WIRING DIAGRAM SMB 50...

Page 13: ...13 Mareli Systems WIRING DIAGRAM PB 40 52...

Page 14: ...14 Mareli Systems NOTES...

Page 15: ......

Page 16: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics MareliSystems IndustrialZone S...

Reviews: