This Manu allows selecting the programming modalities and and the Ignition/Extinguishing time slots.

 

Disable

 

 

Daily

 

Weekly

 

Week

-

End

 

 

Modality

 - It allows selecting the disired modality, or disable all set programming.

1. Enter modification mode through the key 

P3

.

2. Select the chosen modality (Daily, Weekly or Week end).

3. Enable/disable chrono modality through the keys 

P2

.

4. Save the settings through the keys 

P3

.

Programming

The system includes three type of programming: Daily, Weekly, Week end. 

After selecting the desired kind of programming:

1. Select the programming time through the keys 

P4/P6

.

2. Enterthe adjustment modality (selected time will be flashing) through the keys 

P3

.

3. Change the time via keys  

P4/P6

.

4. Save the programmong with the keys 

P3

.

5. Enable (a “V” is displayed) or disable the time slot (a “V” is not displayed”) by 

pressing the keys 

P5

.

Daily

Select the day of the week to program and set the ignition and extinguishing times.

Programs around midnight

Set the clock On of the previous day at the desired time: Ex. 20.30

Set the clock of OFF of the previous day at:  23:59

Set the clock On of the following day at  00:00

Set the clock of OFF of the following day at the desired time: Ex. 6:30

The system turns on at 20.30 on Tuesday and turns off at 6.30 on Wednesday

Weekly

The programs are the same for all days of the week.

Week-end

Choose between 'Monday-Friday' and 'Saturday-Sunday' and then set the switching 

on and off times.

 

 

Monday 

 

 

    ON             OFF 

  09:30           11:15  V 

  00:00           00:00 

  00:00           00:00 

Monday

____________ 

Tuesday 

Wednesday  

Thrusday 

Friday

 

Mon-Fri 

Sat-Sun 

 

USER MENU 2

Menu is accessed by pressing the 

P3 

buttons for 3 seconds .

Keyboard Settings

 

Time and Date

 - Used to set the day, month, year and current time.

Language

 - Menu to modify the language of the LCD board.

Keyboard Menu
Set Contrast

 - Menu used to regulate the display contrast.

Set Minimum Light

 - Menu used to regulate the lighting of the display when the command aren’t used.

Keyboard Address - 

It allows to change the address of the RS485 node. In the RS485 bus it is not possible to 

have more nodes with the same address. It is possible to configure the keyboard as local or remote by changing 

the address (16 for local , 17 for remote).

Node List - 

This menu shows: communication address of the board, typology of the board, firmware code and 

firmware version. Data are not modifiable. The typologies of board that can appear are:

MSTR - Master; 

INP - Input ;  

KEYB - Keyboard; 

 

OUT - Output;

CMPS - Composite;  SENS - Sensor; 

COM - Communication;

Acoustic Alarm 

- It allows to enable or disable the acoustic alarm of the keyboard.

Summary of Contents for CBM 45

Page 1: ...Pellet Water Boiler CBM 45 Assembly and exploitation manual Mareli Systems...

Page 2: ...ion and exploitation manual of the pellet bunker if the device is provided with one The non fulfillment of prescriptions and violation of active regulations and directives may lead to damage and unexp...

Page 3: ...ed service technician to establish whether the equipment is safe There is a risk of thermostat damage and melting the flexible pellet feeding tube To prevent backfire it should be checked if the burne...

Page 4: ...oiler needs to be well levelled thus ensuring its proper venting Attention Fire risk due to flammable materials and liquids Make sure no flammable materials and or liquids are in the vicinity of the h...

Page 5: ...pressure of the water must be equal to 2 bar the maximum to 6 0 bar There must be an available capacity of at least 11 l min Connect the safety heat exchanger according to the hydraulic chart with a...

Page 6: ...installation for user Attention Hazard to life in case of non observation of the safety prescriptions Functions of Individual Elements Strong fanning can lead to flame extinguishing due to excessive...

Page 7: ...a temperature of around 90 is reached Remove the tar from the floor and the heating surfaces by the cleaning spade Boiler Inspection and Maintenance Why is regular maintenance important These are the...

Page 8: ...an be monitored on the display Warranty The manufacturer guarantees correct and reliable operation of the product only when requirements for in stallation and operation are met according to the manual...

Page 9: ...tat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to problems of adjustment of the number of revo...

Page 10: ...ond case the user selects the desired power On the left side of the display are signalled the combustion modality A automatic combustion M manual combustion and the working power of the system Recipe...

Page 11: ...day at the desired time Ex 6 30 The system turns on at 20 30 on Tuesday and turns off at 6 30 on Wednesday Weekly The programs are the same for all days of the week Week end Choose between Monday Fri...

Page 12: ...12 Mareli Systems WIRING DIAGRAM SMB 50...

Page 13: ...13 Mareli Systems WIRING DIAGRAM PB 40 52...

Page 14: ...14 Mareli Systems NOTES...

Page 15: ......

Page 16: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics MareliSystems IndustrialZone S...

Reviews: