Instruction! System damage due to freezing.

When the heating system is not working, it can freeze in cold weather. The electronic control prevents the 

heating system from freezing by starting the circulation pump in forced operation mode at temperatures below 

5°C.

• 

Protect the heating system against freezing by not disconnecting it from power supply.

• 

If possible, leave the heating system permanently switched on.

Temporary boiler decommission

• 

Clean the boiler and empty the ash drawer.

• 

Shut the door to the ash drawer.

Long-term boiler decommission

For long-term boiler decommission (e.g. at the end of the heating period) thoroughly clean the boiler to 

prevent corrosion.

Emergency boiler decommission

If there is danger of explosion, fire, combustion of gases or vapours, you can extinguish the burning process 

with water. End the combustion process with the start/stop button. Do not unplug from power supply.

Avoid condensation and formation of tar

At too low heating power condensation on heating surfaces can be formed.
The condensate flows down into the ash drawer. 

• 

Check the thermometer / pressure gauge whether during operation boiler water temperature remains 

above 65º C.

• 

Heat the boiler repeatedly. By forming soot deposits in normal mode of operation the danger of conden-

sation is decreased.

Dew point of combustion products is 65ºC and therefore the temperature of the products of combustion on 

heating surfaces must not fall below 65ºC. If condensation forms in the burning chamber, this indicates a very 

high water content in the fuel (wet fuel). In such cases condensation may form even at boiler water temper-

atures over 65ºC. Tar is formed under similar conditions (low heating power, low temperature) and further 

more at wrong combustion setting - too little oxygen. 

Tar may be removed only in hot state, for this purpose proceed as follows:

• 

It is best to heat the boiler with softwood.

• 

When a temperature of around 90ºС is reached

• 

Remove the tar from the floor and the heating surfaces by the cleaning spade.

Boiler Inspection and Maintenance

Why is regular maintenance important?

These are the reasons why a regular maintenance of the heating installations is required:

• 

To keep a high energy conversion efficiency and to ensure an economic functioning of the heating in-

stallation (low fuel consumption);

• 

Ensuring a high operational safety;

• 

Ensuring a high ecological combustion;

Offer Your client an annual contract for revision and maintenance. Use original spare parts only.

Checking the operating pressure of the heating system

The red arrow of the pressure gauge must be set to the required operating pressure. Set an operating pressure 

of at least 1 bar. Check the working pressure of the heating installation. If the manometer pointer is under the 

red pointer, then the working pressure is too low. Water must be added.
Instruction!!! Installation malfunctions due to frequent water adding.

When a frequent water addition is performed, depending on the condition of the water, the heating installa-

tion can be damaged due to corrosion and limestone accumulation.

• 

Ensure that the heating installation is air tight;

• 

Check the insulation of the heating installation and the capability of the enlarging pot;

• 

Installation malfunctions due to tension in the material from to temperature differences.

• 

Fill the heating installation in a cold state only (the incoming temperature must not be exceeding 40º С).

• 

Add water through the loading and unloading valve.

• 

Air tight the heating installation.

• 

Check the working pressure again.

Thermal safety of the flow check

The thermal safety guard of the flow ensures a safe functioning of the heating boiler in case of system failure 

if the system cannot lead the heat of the heating boiler out by itself. A malfunction may occur, for example, 

in case of a frozen heating system, water circulation failure etc. For proper functioning of the thermal safety 

guard a sufficient pressure and cooling water are required. Pressure of at least 2 bar and a 11 l/min water debit 

is required.

Summary of Contents for CBM 45

Page 1: ...Pellet Water Boiler CBM 45 Assembly and exploitation manual Mareli Systems...

Page 2: ...ion and exploitation manual of the pellet bunker if the device is provided with one The non fulfillment of prescriptions and violation of active regulations and directives may lead to damage and unexp...

Page 3: ...ed service technician to establish whether the equipment is safe There is a risk of thermostat damage and melting the flexible pellet feeding tube To prevent backfire it should be checked if the burne...

Page 4: ...oiler needs to be well levelled thus ensuring its proper venting Attention Fire risk due to flammable materials and liquids Make sure no flammable materials and or liquids are in the vicinity of the h...

Page 5: ...pressure of the water must be equal to 2 bar the maximum to 6 0 bar There must be an available capacity of at least 11 l min Connect the safety heat exchanger according to the hydraulic chart with a...

Page 6: ...installation for user Attention Hazard to life in case of non observation of the safety prescriptions Functions of Individual Elements Strong fanning can lead to flame extinguishing due to excessive...

Page 7: ...a temperature of around 90 is reached Remove the tar from the floor and the heating surfaces by the cleaning spade Boiler Inspection and Maintenance Why is regular maintenance important These are the...

Page 8: ...an be monitored on the display Warranty The manufacturer guarantees correct and reliable operation of the product only when requirements for in stallation and operation are met according to the manual...

Page 9: ...tat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to problems of adjustment of the number of revo...

Page 10: ...ond case the user selects the desired power On the left side of the display are signalled the combustion modality A automatic combustion M manual combustion and the working power of the system Recipe...

Page 11: ...day at the desired time Ex 6 30 The system turns on at 20 30 on Tuesday and turns off at 6 30 on Wednesday Weekly The programs are the same for all days of the week Week end Choose between Monday Fri...

Page 12: ...12 Mareli Systems WIRING DIAGRAM SMB 50...

Page 13: ...13 Mareli Systems WIRING DIAGRAM PB 40 52...

Page 14: ...14 Mareli Systems NOTES...

Page 15: ......

Page 16: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics MareliSystems IndustrialZone S...

Reviews: