7
DANGER
ELECTRICAL MAINS
Always isolate chiller from power supply before doing any work on it, to prevent damage and health
hazards.
CAUTION
Before carrying out the following operations, carefully read the instructions given by the sanitization prod
-
uct manufacturer and make sure all personal protective equipment (gloves, masks, etc.) is worn correctly.
The sanitization of the product lines must only be carried out by specialized technical service personnel.
During the sanitization operations, attach a warning sign to the tower concerned, to inform any other
personnel that this operation is in progress, and that it is forbidden to dispense beverages.
DANGER
ELECTRICAL MAINS
Always isolate chiller from power supply before doing any work on it, to prevent damage and health
hazards.
ATTENTION
Do not spray water on the device; this could cause electric shocks or fires.
3. Basic Installation
(See also Installation Guide p13)
3.1 UNPACKING INSTRUCTIONS
•The chiller must be handled only in a vertical position. Transporting the appliance in a horizontal position can cause severe damage
to the refrigerator.
•Remove the exterior and interior packing. Packing materials (especially any plastic bags) should be stored out of the reach
of children, as a potential source of danger. When disposing packaging parts, please follow current regulations on the matter,
separating carton from plastic parts.
•Always check that the equipment that is delivered corresponds to the model indicated in the accompanying document.
•The equipment is shipped in a cardboard box. Once the packaging has been removed, check the equipment has not been damaged
in transit; if damage is found, notify the carrier.
3.2 ELECTRICAL INSTALLATION PROCEDURE
When installing the machine, always observe the local regulations and standards. The appliance is supplied with a moulded power
cord. A suitable mains power supply socket should be available within easy access of the appliance so that it can be disconnected
easily after install.
3.3 PLUMBING INSTALLATION PROCEDURE
• Ensure that the equipment is installed according to local plumbing & water regulations.
• Fit a stop valve on a cold water line and attach a 3/8” BSP male fitting, (E.g. 3/4” x 1/2” 311 or washing machine type stop valve).
• Connect water supply lines following the installation drawings.
As per installation guide (starting page 14)
• In case filter systems are used verify that they satisfy the requirements of the legislation in force.
• If the filter is new, turn on water and flush at least 10 liters (2.5 gallon) through the filter before to connect it to the cooler; if the
filter is a used one, connect water inlet to the chiller.
• To ensure that the maximum value of pressure of 3 Bar is not exceeded the chiller integrates a pressure reducer.
• Turn on the water to flush any impurities, dust etc from the inlet hose and water pipe. Allow several litres through. Especially for
new installations.