7

DANGER

ELECTRICAL MAINS

Always isolate chiller from power supply before doing any work on it, to prevent damage and health 

hazards.

CAUTION

Before carrying out the following operations, carefully read the instructions given by the sanitization prod

-

uct manufacturer and make sure all personal protective equipment (gloves, masks, etc.) is worn correctly. 

The sanitization of the product lines must only be carried out by specialized technical service personnel. 

During the sanitization operations, attach a warning sign to the tower concerned, to inform any other 

personnel that this operation is in progress, and that it is forbidden to dispense beverages.

DANGER

ELECTRICAL MAINS

Always  isolate  chiller  from  power  supply  before  doing  any  work  on  it,  to  prevent  damage  and  health 

hazards.

ATTENTION

Do not spray water on the device; this could cause electric shocks or fires.

3. Basic Installation 

(See also Installation Guide p13)

3.1 UNPACKING INSTRUCTIONS

•The chiller must be handled only in a vertical position. Transporting the appliance in a horizontal position can cause severe damage 

to the refrigerator.

•Remove  the  exterior  and  interior  packing.  Packing  materials  (especially  any  plastic  bags)  should  be  stored  out  of  the  reach 

of  children,  as  a  potential  source  of  danger.  When  disposing  packaging  parts,  please  follow  current  regulations  on  the  matter, 

separating carton from plastic parts.

•Always check that the equipment that is delivered corresponds to the model indicated in the accompanying document.

•The equipment is shipped in a cardboard box. Once the packaging has been removed, check the equipment has not been damaged 

in transit; if damage is found, notify the carrier.

3.2 ELECTRICAL INSTALLATION PROCEDURE

When installing the machine, always observe the local regulations and standards. The appliance is supplied with a moulded power 

cord. A suitable mains power supply socket should be available within easy access of the appliance so that it can be disconnected 

easily after install.

3.3 PLUMBING INSTALLATION PROCEDURE

• Ensure that the equipment is installed according to local plumbing & water regulations. 

• Fit a stop valve on a cold water line and attach a 3/8” BSP male fitting, (E.g. 3/4” x 1/2” 311 or washing machine type stop valve).

•  Connect water supply lines following the installation drawings.

 

As per installation guide (starting page 14)

• In case filter systems are used verify that they satisfy the requirements of the legislation in force.

• If the filter is new, turn on water and flush at least 10 liters (2.5 gallon) through the filter before to connect it to the cooler; if the 

filter is a used one, connect water inlet to the chiller.

• To ensure that the maximum value of pressure of 3 Bar is not exceeded the chiller integrates a pressure reducer.

• Turn on the water to flush any impurities, dust etc from the inlet hose and water pipe. Allow several litres through. Especially for 

new installations.

Summary of Contents for FRIIA

Page 1: ...1 Instruction Manual Machine P N 1000864 1000865 FRIIA...

Page 2: ...ler to Boiler Cable 1501180 1m length 3 8 Tube water 1800627 1m length 6mm Tube CO2 1800628 User Manual n a It is highly recommended to fit a water regulator to the supply feed In the event of mechani...

Page 3: ...ment in good working order and do not allow any modifications unless authorised by the manufacturer This document shall be applied to equipment intended for the EC market only Introduction A Model Num...

Page 4: ...ollowing safety symbols to draw the operator s attention to all operations which must be strictly observed in order to prevent injury to persons or damage to the equipment DANGER Shows the existence o...

Page 5: ...conditions specified in the safety regulations in force CAUTION ELECTRICAL REQUIREMENTS The electrical circuit must be correctly earthed and connected by means of a suitable differential safety break...

Page 6: ...force in the country of use WARNING WATER SUPPLY Connect the water dispenser exclusively to a line of drinkable water supply WARNING WATER SUPPLY In order to avoid accidental flooding due to losses t...

Page 7: ...parating carton from plastic parts Always check that the equipment that is delivered corresponds to the model indicated in the accompanying document The equipment is shipped in a cardboard box Once th...

Page 8: ...equipment and located in such a way the power cable and water hose do not form an obstruction The appliance must not be installed where water jets can be generated Do not spray water on the device th...

Page 9: ...allation procedures have been carried out Ensure water inlet is open Before supplying power to the unit check water and Carbon Dioxide lines do not leak Plug the chiller into a suitable socket switch...

Page 10: ...sure values set on the pressure reducer then fully close the bottle with the valve 2 Remove the pressure reducer or disconnect the high pressure hose from the bottle if fitted Check the condition of t...

Page 11: ...cartridge with a sanitizing filter recommended by Marco and fill with clean water and with sanitizing fluid in the concentration and contact time recommended by the manufacturer 3 Disconnect the water...

Page 12: ...12 6 Troubleshooting Contact Marco service...

Page 13: ...369 437 600 600 100 min 275 200 Applies to model s 1000850 1000851 where is blank or one or more alphanumeric characters DRAWN BY DWG NO PANEL REMOVAL DESCRIPTION PJT 20 08 14 187 C O FRIIA Assembly...

Page 14: ...14 105mm 4 32mm 1 82 5mm Scale 1 1 For drip tray only 100mm NOTE Check scale of template before cutting Scale should be 1 1 FRIIA Font Counter Cut Out Check scale of template before cutting...

Page 15: ...15 Recommended Plumming...

Page 16: ...16 Power cord socket Power switch Thermostat control water in 3 8 CO2 connection 8mm tube Cold CO2 water out 1 4 CO2 pressure release valve Chiller Installation...

Page 17: ...17 Boiler Installation 1 2 3 4...

Page 18: ...Font Installation 32mm 1 1 No Drip Tray 130 500mm 1 3 0 5 0 0 m m 50mm Hosing should be trimmed to ensure continuous drop from font to boiler 100mm 18...

Page 19: ...1 105mm 4 2 Drip Tray sold seperately p n 2300268 130 500mm 1 3 0 5 0 0 m m 50mm Hosing should be trimmed to ensure continuous drop from font to boiler 100mm The drain outlet to the drip tray should...

Page 20: ...20 Connecting Hoses COLD HOT VENT POWER Chiller to boiler connector Vent Hot Water Cold Water Power 7mm 8mm HOT VENT COLD POWER CHILLER TO BOILER CONNECTION COLD...

Page 21: ...ce Panel 2 3 1 7 6 5 4 Set Up Single Button Font default is 3 button font Off Off Descale weeks Filter Litres Set Pin Next 2 3 UC MIX BOTH C Factory preset Mode Temp Units Next 6 85 183 5 C Factory pr...

Page 22: ...n Ventilation grilles cut in base panel and base plinth a grille must also be cut out at the top of the cabinet Please Note In all cases remove the back panel from the cabinet 50 65 265 The cabinet ma...

Page 23: ...23 Marco Beverage Systems Limited 74 Heather Road Sandyford Business Park Dublin 18 Ireland Tel 00353 0 1 295 2674 Email sales marcobeveragesystems com...