TROUBLESHOOTING

L

- Check the effectiveness of the battery power supply (voltage activity);
- Check if the fuse has blown;
- Check for any foreign matter present in-between the pump gear drives. To do this,
  disconnect the power supply and unscrew the four fixing screws, remove the pump front
  cover plate and inspect the pump chamber. Replace the cover plate in the same initial
  position after inspection;
- Avoid running the pump dry for more than a few minutes. Pumps found defective that
  have run dry in the absence of fluid are not covered by warranty;

- The average life span of the motor commutator brushes is approximately 1000 hours

  under normal operating conditions. Stoppages are possible due to brush wear and tear
  after such a time period.

- The pump is fitted at a height greater than 

 above the fluid level

1,5 m

;

- The pump has run dry for too long a period;
- Long periods of inactivity. In this case it is advisable to add liquid directly into the pump
  chamber before start-up. It is also advisable to add, before running the pump, a drop of
  lubricating oil inside the pump only;
- Air leak at the suction pipe due to the following reasons:
  Possible cuts in the pipe, inadequate hose clamps, malfunctioning of the filter due to
  defective/worn seals or filter clogged;
- Air leak at the pump front plate cover due to the following reasons:
  Loose fixing screws, poor effectiveness of the seal;
- Faulty electrical cable connections;
- Presence of obstructions or restrictions in the suction or delivery pipes or the use of
  special devices(eg. automatic spray pistol or aqua-stop);
- Presence of liquid loops in the outlet tube.

L-2

WHY THE PUMP WILL NOT PRIME ITSELF?

L-1

L-1

CHECK POINTS IF THE PUMP HAS STOPPED OR WILL NOT START

No particular maintenance is required if the pump is utilized for the transfer of diesel fluids. 
If it is expected that the pump will not be used for a period of at least 30 days, especially in 
the case of usage with fresh or salty water, it is advisable to run fresh water through the 
pump and to then loosen the pump front plate screws. 

L-3

GOOD PRACTICES ENSURING A WELL FUNCTIONING PUMP 

To ensure the correct directional flow of the fluid as indicated by the arrow on the top of the 
pump, it is necessary to connect the positive pole 

of the battery supply to the red wire 

( + ) 

on the motor end-cap and the negative pole 

to the black wire. Electrical 

 

( - ) 

connections

must be made using adequate terminal blocks and connectors ensuring a 

 

tight fitment of

the electrical cables. Bad wiring can cause power losses and/or 

 

overheating of the cabling 

itself.

Summary of Contents for 164 662 12 - UP2/A 12V

Page 1: ...14 Rev 03 2014 S p A ELETTROPOMPA AUTOADESCANTE PER TRAVASO LIQUIDI SELF PRIMING ELECTRIC PUMP FOR TRANSFERRING VARIOUS LIQUIDS AVVERTENZE D USO INSTRUCTIONS FOR USE 164 662 12 UP2 A 12V 164 662 13 UP2 A 24V ...

Page 2: ...l adescamento pompa When starting the pump or when emptying the tank slightly open the small valve in order to let the air out and facilitate the pump priming Una volta azionata la pompa richiudere la valvolina As soon as the pump is operating close the small valve E obbligatorio l uso di un vaso di espansione con capacità minima di 0 5 litri It is mandatory to always use an expansion tank of mini...

Page 3: ...E E AMBIENT CONDITIONS C TECHNICAL DETAILS B APPLICATIONS F There are numerous fields of applications for the pump however only exclusively with the allowed liquids mentioned Main use as automatic pump for freshwater and sanitary water systems on boats camper Self priming gear pump integrated check valve and pressure switch to be used as automatic pump for boats trucks camper etc Nichel plated bra...

Page 4: ... recommended that the use of the pump be according to normative safety standards and also as per the precautions listed below I 1 PACKAGING ENVIRONMENTAL DISPOSAL I 2 PRELIMINARY CHECKS Check that there has been no damage to the pump during transportation or storage Both inlet and outlet ports should be carefully cleaned removing possible dust or residual packaging material Verify that the availab...

Page 5: ...e of the filter is advisable Utilize tubes and connection pieces that are resistant to the fluid types handled and avoid any possible environmental dispersion The electrical installation of the pump must include a protection fuse which is suitably rated as indicated on the motor label and sized with reference to the chosen point of application WARRANTY EXPIRES IF NO FUSE IS UTILIZED Always mount t...

Page 6: ...de the pump only Air leak at the suction pipe due to the following reasons Possible cuts in the pipe inadequate hose clamps malfunctioning of the filter due to defective worn seals or filter clogged Air leak at the pump front plate cover due to the following reasons Loose fixing screws poor effectiveness of the seal Faulty electrical cable connections Presence of obstructions or restrictions in th...

Page 7: ...s again Check under conditions of maximum operating pressure that the motor current value is within the motor label specifications 1 The Warranty period is 2 years from date of purchase on production of the appropriate sales invoice 2 Should the original sales invoice not be available then the 2 year warranty period will be valid from date of production 3 The Warranty becomes null and void in the ...

Page 8: ...NGRANAGGIO TRAINANTE 15 1 O RING 16 1 PIATTELLO 17 4 VITE 18 1 VALVOLA DI NON RITORNO 19 1 O RING 20 1 TAPPO DI SFIATO 21 1 PRESSOSTATO 22 2 PORTAGOMMA 23 4 ANTIVIBRANTE Pos Q ty Description 1 1 PUMP BODY 2 1 SHAFT 3 1 RUBBER LIP SEAL 4 2 ROD 5 1 PUMP FRAME 6 1 BRUSH HOLDER 7 1 COMPENSATION SPRING 8 1 BALL BEARING 9 1 ARMATURE 10 2 WASHER 11 NUT 12 IDLE GEAR 2 1 Pos Q ty Description 13 1 KEY 14 4 ...

Page 9: ...14 2014 S p A I T E N G INGOMBRI DIMENSIONS P 10 81 52 29 42 166 60 38 102 12 5 116 52 113 53 8 80 18 ...

Page 10: ...15 2014 S p A I T E N G DIAGRAMMI DIAGRAMS Q DIAGRAMMA PORTATA FLOW RATES DIAGRAM DIAGRAMMA ASSORBIMENTI AMPERE DRAW DIAGRAM 0 2 4 6 8 10 12 0 0 5 1 1 5 2 bar l min 0 2 4 6 8 0 0 5 1 1 5 2 bar A ...

Page 11: ...valid for all products which are produced in accordance with the technical documentation which is a part of this declaration For verification of conformity with regard to Electromagnetic Compatibility the following standards are applied E conforme alla Direttiva 2004 108 CE ex 89 336 CE relativa alla compatibilità elettromagnetica Is in conformity with the Directive 2004 108 EC ex 89 336 EC relati...

Page 12: ...I T E N G 17 2014 S p A NOTE NOTES ...

Page 13: ...18 2014 S p A NOTE NOTES I T E N G ...

Page 14: ...19 2014 S p A NOTE NOTES I T E N G ...

Page 15: ...it Marco S p A Via Mameli 10 25014 Castenedolo Brescia Italy tel 39 030 2134 1 Fax 39 030 2134 300 Per ulteriori informazioni vedere sito internet www marco it Marco S p A Via Mameli 10 25014 Castenedolo Brescia Italy tel 39 030 2134 1 Fax 39 030 2134 300 ...

Reviews: