1. Chiller Specification
Mains water pressure required
downstream of any filter systems:
0.1~0.4MPa ( 1~4 bar) (100~400kPa) ( 15.4~61.6 psi)
If mains pressure is below 1 bar or the
flow rate is less than 2L/min:
Fit a device capable of increasing the mains pressure (autoclave or similar).
ensure your water net is able to supply at least 2L/min water flowrate.
Water connection:
3/8” Quick connection fitting.
Electrical requirements 230V:
Two 13 amp sockets operating on 230V single phase.
Machine location:
The machine must be located in a well ventilated space, at least 10cm (3.9inch)
around back and top for ventilation.
1.1 Installation Requirements
Model
1000201
1000202
Description
FRIIA Lite Chiller
FRIIA Lite Chiller/Carbonator
Power Supply Voltage & Frequency (V/Hz):
230V ~ 50/60Hz
220-240V ~ 50/60Hz
Power Consumtion:
177W
220W
Colling capacity:
>12 L/h ( ΔT ≥ 10°C )
>12 L/h ( ΔT ≥ 10°C )
Pouvoir Hydrogène PH
6.5 ~ 8.5
6.5 ~ 8.5
Applicable Water Pressure
0.1 ~ 0.4Mpa
0.1 ~ 0.4Mpa
Room Temperature
4 ~ 38°C
4 ~ 38°C
Applicable Inlet Water
TDS<350ppm
TDS<350ppm
Particular removable
>99.7%
>99.7%
Smell/Taste
Remove
Remove
Visible object
Remove
Remove
Chlorine Reduction
>97.4%
>97.4%
Cysts
>99.99%
>99.99%
Carbonation tank Capacity
/
0.45L
Volume/Gas
/
>2.5V/gas
Sparkling water flow rate
/
≥1.8L/min
CO2 Reducer
/
Micro CO2 Reducer thread ACME
Rechargeable CO2 Bottle
/
60lt / 360-410gr
Cooling System
Ice Bank
Ice Bank
Cold Water Flow Rate
≥1.5L/min
≥1.5L/min
Cooling Power
100W
100W
Product Size
279x468x412mm (WxDxH)
279x468x412mm (WxDxH)
Weight (Net/Gross) (Kg)
17.8/20.7 kg
18.3/21.2 kg