25
7. Chiller Troubleshooting
Cold & Sparkling Model
25
●
Illuminated
Flash
○
OFF
Product 1000202
Filter
Cooling
Cylinder
Cause
Solution
-RED
-BLUE
-YELLOW
Power ON + Cooling ON + Cylinder
FULL
○
○
Normal
Power ON + Cooling ON + Cylinder
EMPTY
○
●
CO2
reminder
Replace the cylinder
Power ON + Cooling fi
Cylinder FULL
○
●
○
Normal
Power ON + Cooling fi
Cylinder EMPTY
○
●
●
CO2
reminder
Replace the cylinder
Filter re Cooling ON +
Cylinder FULL
●
○
Filter needs
replacing
Replace the filter, reset the
filter recover button (located
beside filter)
Filter re Cooling ON +
Cylinder EMPTY
●
●
Filter & CO2
reminder
Replace the filter ,reset the
filter recover button. Replace
the cylinder
Filter re Cooling fi
Cylinder FULL
●
●
○
Filter needs
replacing
Replace the filter, reset the
filter recover button (located
beside filter)
Filter re Cooling fi
Cylinder EMPTY
●
●
●
Filter & CO2
reminder
Replace the filter, reset the
filter recover button. Replace
the cylinder
Cooling switch off. Or Refrigeration
system problem
○
○
○
Cooling
switch off. Or
cooling NTC
fault.
Turn on the cooling switch.
Then check it and replace the
NTC in the ice bank
No water in Icebank
○
○
Shortage of
water
Check the water supply
Pump continues work exceed 5min
without operation
○
○
No water in
the cold pipes
Check the water supply
Water leakage
Water leakage
Power off. Check all pipes and
connecters.
Water Overfilling in Icebank
●
○
○
Water leakage
Power off. Check all pipes and
connecters. Drain water in
the icebank tank.