Failure
Cause
Solution
Low water pressure
Check the tap water
Filter not replaced in time, beyond the use
time
Replace the filter
Unsuitable water
temperature
Over consumption of water in a short time
Wait a moment, and water is available again
The cooling switch is not turned on
Turn on the cooling switch at the rear of the
machine
Water leakage
Pipe not connected properly
Inspect the connector to connect the pipe
properly
Water pipe and PE pipe bursting
Replace the water pipe and PE pipe
Electric leakage
Machine in poor contact with ground
Use a socket with earth wire, making the
machine grounded properly
Noisy operation
Not installed steadily or levelled
Place the machine on a steady & solid surface;
level the machine
A few pipes are touching some parts inside
the appliance, thus causing it to vibrate
Adjust the position of pipes, making sure they
don’t touch any other parts
Machine fails to run
Power supply not put through
Switch on power supply
The compressor will not
start
Power failure
Check that there is voltage in the plug
The compressor is faulty
Replace it
The water is cold but the
compressor is working con-
tinuously or non- stop
Little ventilation
Replace the appliance away from the wall
The condenser is dirty or covered
Clean the condenser or free it of its obstacles
The room temperature is higher than 40
°
It’s normal that the appliance works at a
continuously high room temperature
The compressor works
continuously, but the water
is not cold
Gas leak from the cooling system
Contact a refrigeration engineer
The compressor is faulty
Replace the compressor.
Cold water comes out
slowly or not at all
The pump is blocked
Check it and replace the pump
Clogged water filter
Replace the filter
The soda water is not very
fizzy or not at all
The pressure of CO2 reducer is set less than
4 bars
Check and replace the gas reducer
Only gas comes out of the
carbonated water outlet
The pump is blocked
Check and replace the pump connected to the
water in pipe of the carbonation tank
There is no water in the line