background image

1

Instruction Manual
Machine P/N: 1000201#, 1000202# 

FRIIA LITE

Summary of Contents for 1000201

Page 1: ...1 Instruction Manual Machine P N 1000201 1000202 FRIIA LITE ...

Page 2: ...aptor 1400822 3 8 Y x 2 Way Divider 1400814 3 8 x 3 8 elbow Fixing bracket Power cable User manual n a It is highly recommended to fit a water regulator to the supply feed In the event of mechanical failure a regulator set correctly will ensure the water supply is cut Marco suggests 10 litres continuous flow FRIIA Lite Chiller Part no Chiller 230Vac 50 60Hz 1000201 2m length 3 8 Tube water 1800627...

Page 3: ...allow any modifications unless authorised by the manufacturer WARNING The refrigerant R600 Iso Butane is flammable and it must be handled only by competent and responsible operators under the conditions specified in the safety regulations in force Risk of Fire Flammable materials Introduction A Model Number and name B Rated Voltage C Rated Power D Product serial code mmyyxxxxxx E Contact details F...

Page 4: ...Description FRIIA Lite Chiller FRIIA Lite Chiller Carbonator Power Supply Voltage Frequency V Hz 230V 50 60Hz 220 240V 50 60Hz Power Consumtion 177W 220W Colling capacity 12 L h ΔT 10 C 12 L h ΔT 10 C Pouvoir Hydrogène PH 6 5 8 5 6 5 8 5 Applicable Water Pressure 0 1 0 4Mpa 0 1 0 4Mpa Room Temperature 4 38 C 4 38 C Applicable Inlet Water TDS 350ppm TDS 350ppm Particular removable 99 7 99 7 Smell T...

Page 5: ...in a well ventilated place where the air can flow in and out Great care must be taken to prevent CO2 leaks throughout the system including the gas cylinders If a CO2 leak is suspected especially in a small area ventilate the contaminated area at once persons exposed to high concentrations of CO2 will experience trembling swiftly followed by unconsciousness and suffocation DANGER ELECTRICAL MAINS A...

Page 6: ...any possible risk CAUTION LOW TEMPERATURE If the equipment is exposed to temperatures lower than O C the water inside could turn to ice and damage the equipment CAUTION SANITISATION Before sanitising the equipment carefully read the instructions given by the sanitisation product manufacturer and put on all the necessary personal protective equipment gloves masks etc Ensure that the premises are we...

Page 7: ...GER PRESSURE REDUCER Never connect CO2 cylinder directly to the equipment Always use a suitable pressure reducer ATTENTION Do not spray water on the device this could cause electric shocks or fires WARNING Do not damage the refrigerant circuit WARNING Do not store explosive substances such as aerosol cans with a flammable propellant in the appliance ATTENTION This appliance is inteded to be used i...

Page 8: ...INSTALLATION PROCEDURE When installing the chiller always observe the local regulations and standards The chiller is supplied with a moulded power cord A suitable mains power supply socket should be available within easy access of the chiller so that it can be disconnected easily after install 3 3 PLUMBING INSTALLATION PROCEDURE Ensure that the chiller is installed according to local plumbing wate...

Page 9: ...vent any dirt from the valve Close the cylinder valve after few seconds GAS CYLINDER LOCATION To prevent the risk of injury or damage the CO2 cylinder must always be kept in a vertical position against a wall held in place by a chain and fixed to a bracket Do not expose the bottle to heat sources or very low temperatures PRESSURE REDUCERS There are different type of CO2 cylinder available Always u...

Page 10: ...ld cause electric shock or fires 4 OPERATING 4 1 BEFORE USING CHILLER Before connecting the chiller to the power source let it stand upright for approximately 2 3 hours this will reduce the possibility of a malfunction Check that all installation procedures have been carried out Ensure water inlet is open Ensure CO2 valve is full stop Before supplying power to the chiller check water and CO2 lines...

Page 11: ...2 CYLINDER The cyclinder must be replaced when the needle of the reducer high pressure gauge is in the red segment or when the CO2 light on the front of the chiller flashes 1 Record the pressure values set on the pressure reducer then fully close the bottle with the valve 2 Remove the pressure reducer or disconnect the high pressure hose from the bottle if fitted Check the condition of the gaskets...

Page 12: ...12 5 FRIIA Lite Installation Guide Font Positioning ...

Page 13: ...13 100mm 4 32mm 1 82 5mm Scale 1 1 For drip tray only 100mm NOTE Check scale of template before cutting Scale should be 1 1 FRIIA Font Counter Cut Out Check scale of template before cutting ...

Page 14: ...14 Recommended Plumbing ...

Page 15: ... Water In 3 8 CO2 Connection 8mm tube 1 4 Cold Output to Font Chiller Installation Cooling Switch Compressor on Electrical Connection to Font Electrical Connection to Boiler Cable Supplied with Font Filter CO2 Hatch ...

Page 16: ...ced Flashing indicates a shortage of water Cooling Light Lights up to indicate the chiller is ready to use allow 70 120min for the chiller to get down to temperature Flashing indicates the compressor is ON Sparkling Water Light Lights up to indicate the CO2 Cylinder is empty When the light is off this inicates the CO2 Cylinder is full of gas ...

Page 17: ...17 Boiler Installation 1 2 3 4 The boiler paired with the chiller is the MIX Boiler UC3 p n 1000880 For more details on boiler installation please consult boiler instruction manual ...

Page 18: ...18 Font Installation 32mm 1 1 No Drip Tray ...

Page 19: ...19 Font Installation 32mm 1 100mm 4 2 Drip Tray sold seperately p n 2300268 The drain outlet to the drip tray should be plumbed to waste ...

Page 20: ...20 COLD 1 4 CHILLER TO BOILER CONNECTOR 1501180 HOT 8mm VENT ELECTRICAL FONT CONNECTION Connecting Hoses Vent Hot Water Cold Water Power 1 4 8mm Vent connects to boiler vent outlet ...

Page 21: ...st also be cut out at the top of the cabinet Please Note In all cases remove the back panel from the cabinet 50 65 265 The cabinet may be ventilated in many ways provided there are cut outs placed near the base and another near the top of the cabinet to take advantage of natural circulation Cabinet temperature Max 35 C if more air is not being evacuated efficiently it may cause cooling issues or p...

Page 22: ...22 Exhaust fan Intake fan optional Exhaust fan Intake fan optional Exhaust fan Exhaust fan Fan Installation Cabinet Ventilation 22 ...

Page 23: ...carbonated water until only CO2 is dispensed 4 Close the CO2 cylinder and dispense carbonated water to remove CO2 pressure completely 6 2 SANITISING 1 Turn off Electrical Power Supply 2 Turn the compressor off by turning off the cooling switch at the back of the machine 3 Replace the filter cartridge with a sanitising filter recommended by Marco and fill with clean water and with sanitising fluid ...

Page 24: ...e dispense water from the font to clear the system of any sedements and then turn on the water supply 6 The chiller must use an earthed three pin socket and a reliable creepage protection switch 7 Never use organic solvents such as gasoline to clean the chiller it is strictly prohibited to splash water onto the chiller 8 Never increase the length of the power supply cord 9 If the supply cord is da...

Page 25: ...utton Replace the cylinder Filter reminder Cooling finished Cylinder FULL Filter needs replacing Replace the filter reset the filter recover button located beside filter Filter reminder Cooling finished Cylinder EMPTY Filter CO2 reminder Replace the filter reset the filter recover button Replace the cylinder Cooling switch off Or Refrigeration system problem Cooling switch off Or cooling NTC fault...

Page 26: ...the filter reset the filter recover button located beside filter Refrigeration system problem Cooling NTC fault Check and replace the cooling NTC in the ice bank No water in Icebank Turn off Refrigeration system and pump until water is full Waiting for the machine purifying water No water in Icebank exceed 10min Shortage of water Check the water supply Press any button resume Water leakage Water l...

Page 27: ...pply not put through Switch on power supply The compressor will not start Power failure Check that there is voltage in the plug The compressor is faulty Replace it The water is cold but the compressor is working con tinuously or non stop Little ventilation Replace the appliance away from the wall The condenser is dirty or covered Clean the condenser or free it of its obstacles The room temperature...

Page 28: ...Marco Beverage Systems Limited 74 Heather Road Sandyford Business Park Dublin 18 Ireland Tel 00353 0 1 295 2674 Email sales marcobeveragesystems com ...

Reviews: