8
9
www.
imPower
Dealer
.com
8
9
Two Speed Connections with Timer
If you had a single speed motor prior to this installation, you will need to run new
conduit with 4 wires (High Speed, Low Speed, Neutral, and Ground) to properly
operate with the two speed timer.
Step 1:
Remove the three screws holding the top control enclosure onto the
motor. Carefully lift the top panel and turn it over to expose the inside of the
terminal box.
Step 2:
Run the HIGH Speed, LOW Speed, L2, and GROUND wires from the
conduit cable through the open on the right side of the motor (shaft facing
away from you).
Step 3:
Connect the wire for the HIGH Speed from the timer to the opening
directly across from the BLACK wire on the terminal block.
Step 4:
Connect the wire for the LOW Speed from the timer to the opening
directly across from the RED wire on the terminal block.
Step 5:
Connect the L2 to the opening directly across from the WHITE wire
on the terminal block.
Step 6:
Connect the GROUND to the opening directly across from the
GREEN/YELLOW wire on the terminal block.
Step 7
: Screw in the conduit connector into the terminal box on the right side of
the terminal box (shaft facing away from you).
Step 8:
Carefully fold the extra wires inside the terminal box and place the
top control panel back on top of the terminal box.
Step 9:
Tighten the three screws into the terminal box while applying light
pressure to the top control enclosure.
- 1 -
Safety Considerations
The following definitions are used as safety considerations on the
Evergreen IM motor and in this manual. Please read and observe all
of these safety concerns.
SAFETY
SYMBOLS
Installation and service of this motor should be attempted only by
trained service technicians familiar with the Evergreen instructions
and training manual.
This motor should be installed in accordance with accepted practices
and installation instructions, and in compliance with all national and
local codes.
REG7232_EvergreenIM_Reprint.indd 1
4/28/10 2:05:19 PM
When servicing the pool pump filter motor, always disconnect the main
power from the unit. It is also good practice to confirm that the power is off
with a meter.