Automation Controller Signal Line Connection 

These steps as outlined below are for connection of the imPower motor to an 

automation controller.  You will need the optional low voltage cable connection 

kit P/N 391-200-01 (15' cord) or P/N 391-200-02 (25' cord). 

Step 1:

  Remove the three screws holding the top control enclosure onto the 

terminal box.  Carefully lift the top panel and turn it over to expose the inside of 

the terminal box. 

Step 2:

  Run the L1L2, and GROUND wires from the conduit cable through the 

open on the right side of the motor (shaft facing away from you). 

Step 3:

  Connect L1 from the automation controller to the opening directly across 

from the BLACK wire on the terminal block. 

Step 4: 

 Connect the L2 to the opening directly across from the WHITE wire on 

the terminal block. 

Step 5:

  Connect the GROUND to the opening directly across from the  

GREEN/YELLOW wire on the terminal block. 

Step 6: 

 Screw in the conduit connector into the terminal box on the right side of 

the terminal box (shaft facing away from you). 

Step 7: 

 On the rear of the terminal box, remove the small black plug. 

Step 8:

  Plug the connector end of the low voltage cable (P/N 391-200-01 or  

P/N 391-200-02) into the connector on the underside of the top control panel. 

Step 9:

  Screw in the low voltage conduit onto the rear of the terminal box.   

Run the low voltage cable to the automation control box.   

- 1 -

Safety Considerations

The following definitions are used as safety considerations on the 

Evergreen IM motor and in this manual. Please read and observe all  

of these safety concerns. 

SAFETY 

SYMBOLS

Installation and service of this motor should be attempted only by  

trained service technicians familiar with the Evergreen instructions  

and training manual. 

This motor should be installed in accordance with accepted practices  

and installation instructions, and in compliance with all national and  

local codes. 

 REG7232_EvergreenIM_Reprint.indd   1

4/28/10   2:05:19 PM

When servicing the pool pump filter motor, always disconnect the main  

power from the unit.  It is also good practice to confirm that the power is off 

with a meter.

Summary of Contents for imPower

Page 1: ......

Page 2: ...is not only saves the Earth s precious resources but also saves the consumer hundreds of dollars per year in energy costs Why Choose Us Our fast response to customer questions unmatched engineering ex...

Page 3: ...the Existing Motor from Pump 6 Single Speed Connection with Timer 7 Two Speed Connections with Timer 9 Automation Controller Signal Line Connection 11 Changing Default Low Speed 14 imPower Motor Conne...

Page 4: ...be attempted only by trained service technicians familiar with the Evergreen instructions and training manual This motor should be installed in accordance with accepted practices and installation inst...

Page 5: ...three selectable speeds either through the use of the patent pending auto speed switch feature top panel push buttons external multi speed timers or through external automation controls RB003 Model Nu...

Page 6: ...se the seal from the existing motor when installing the imPower motor Remove the screw holding the seal plate onto the motor Step 5 Remove the pump motor by removing the four bolts holding the motor t...

Page 7: ...n the right side of the terminal box shaft facing away from you Step 7 Carefully fold the extra wires inside the terminal box and place the top control panel back on top of the terminal box Step 8 Tig...

Page 8: ...d for 2 hours and then the motor will automatically switch to the low speed Note in the installation manual there is a section that will show you how to change the default low speed setting The total...

Page 9: ...opening directly across from the WHITE wire on the terminal block Step 6 Connect the GROUND to the opening directly across from the GREEN YELLOW wire on the terminal block Step 7 Screw in the conduit...

Page 10: ...y power to the motor This connection allows the high speed and low speed to be operated at any dura tion set by the multi speed timer At no point will the motor automatically do down to the default lo...

Page 11: ...tly across from the GREEN YELLOW wire on the terminal block Step 6 Screw in the conduit connector into the terminal box on the right side of the terminal box shaft facing away from you Step 7 On the r...

Page 12: ...rol panel Step 14 Replace and tighten the screws to mount the seal plate onto the motor Step 15 Put a NEW pump seal into the seal plate and onto the motor shaft Handle and lubricate seal per manufactu...

Page 13: ...he automation controller via the buttons on the top control panel The override will continue until the motor is either powered off by the automation controller or a new speed is requested by the autom...

Page 14: ...within the first two minutes of operation The low speed LED will blink for three seconds followed by 15 blinks of the medium speed LED The low speed LED blinks for three seconds to identify that the...

Page 15: ...15 www imPowerDealer com 15 imPower Motor Connection Diagram Accessories Description P N 15 ft Low Voltage Cable 391 200 01 25 ft Low Voltage Cable 391 200 02...

Page 16: ...Need Additional imPower Help Contractor Hotline 800 683 9144 imPower Website www imPowerDealer com...

Reviews: