Automation Controller Signal Line Connection
These steps as outlined below are for connection of the imPower motor to an
automation controller. You will need the optional low voltage cable connection
kit P/N 391-200-01 (15' cord) or P/N 391-200-02 (25' cord).
Step 1:
Remove the three screws holding the top control enclosure onto the
terminal box. Carefully lift the top panel and turn it over to expose the inside of
the terminal box.
Step 2:
Run the L1, L2, and GROUND wires from the conduit cable through the
open on the right side of the motor (shaft facing away from you).
Step 3:
Connect L1 from the automation controller to the opening directly across
from the BLACK wire on the terminal block.
Step 4:
Connect the L2 to the opening directly across from the WHITE wire on
the terminal block.
Step 5:
Connect the GROUND to the opening directly across from the
GREEN/YELLOW wire on the terminal block.
Step 6:
Screw in the conduit connector into the terminal box on the right side of
the terminal box (shaft facing away from you).
Step 7:
On the rear of the terminal box, remove the small black plug.
Step 8:
Plug the connector end of the low voltage cable (P/N 391-200-01 or
P/N 391-200-02) into the connector on the underside of the top control panel.
Step 9:
Screw in the low voltage conduit onto the rear of the terminal box.
Run the low voltage cable to the automation control box.
- 1 -
Safety Considerations
The following definitions are used as safety considerations on the
Evergreen IM motor and in this manual. Please read and observe all
of these safety concerns.
SAFETY
SYMBOLS
Installation and service of this motor should be attempted only by
trained service technicians familiar with the Evergreen instructions
and training manual.
This motor should be installed in accordance with accepted practices
and installation instructions, and in compliance with all national and
local codes.
REG7232_EvergreenIM_Reprint.indd 1
4/28/10 2:05:19 PM
When servicing the pool pump filter motor, always disconnect the main
power from the unit. It is also good practice to confirm that the power is off
with a meter.