Step 11:
Replace the impellor. Make sure that the impellor can spin freely in the
housing.
Step 12.
Replace the diffuser.
Step 13:
Replace and tighten the bolts that retain the motor/seal plate assembly
to the pump.
Step 14:
Prime the pump.
Step 15:
Reapply power to the motor.
Note that with this type of connection, the motor will operate on the high speed
for 2 hours, and then the motor will automatically switch to the low speed. Note,
in the installation manual, there is a section that will show you how to change the
default low speed setting.
The total timer on time should be selected so that the pool can meet the total
number of turns as required by local/state regulations.
The user can also override the operational speed currently running via the
buttons on the top control panel. The override will continue until the motor is
powered off by the single speed timer. A new speed can also be selected while in
override mode.