Error
Code
Details of Error code
Display
Coping strategies
11
Main CPU failed to receive firmware
for rewriting sent from DM860A (when
an error occurred).
U p d a t i n g
f a i l
1 1
Turn off and on the power.
Updating starts automatically.
12
There was invalid data in the firmware
for rewriting sent from DM860A to
Main CPU (when a Check Sum error
occurred).
U p d a t i n g
f a i l
1 2
Turn off and on the power.
Updating starts automatically.
13
The deletion of block data failed
before Main CPU was rewritten.
E r a s e
f a i l
1 3
Turn off and on the power.
Updating starts automatically.
14
The rewriting of block data failed
when Main CPU was rewritten.
U p d a t i n g
f a i l
1 4
Turn off and on the power.
Updating starts automatically.
15
The data verification was invalid after
Main CPU was rewritten.
U p d a t e C h e c k N G
1 5
Turn off and on the power.
Updating starts automatically.
20
Failure to acquire (Boot Loader Mode)
IP address before rewriting DM860A
(AutoIP).
C o n n e c t i o n F a i l 2 0
Check the network connection.
Carry out the update in an environment
that has little network load.
21
Failure to acquire (Boot Loader Mode)
IP address before rewriting DM860A
(when timed out).
C o n n e c t i o n F a i l 2 1
Check the network connection.
Carry out the update in an environment
that has little network load.
22
Log-in to DPMS failed.
L o g i n
f a i l e d
2 2
Reset and update again.
Carry out the update in an environment
that has little network load.
23
Line, etc., is busy when logging into
DPMS.
S e r v e r
i s
b u s y 2 3
Carry out the update in an environment
that has little network load.
24
Connection to DPMS failed.
C o n n e c t i o n F a i l 2 4
Check the network connection.
Carry out the update in an environment
that has little network load.
25
Mode change failure of DM860A.
C o n n e c t i o n F a i l 2 5
Reset and update again.
26
Data acquisition failed (timed out)
when firmware of Main CPU was
downloaded. Received Package
Version is wrong.
D o w n l o a d
f a i l
2 6
Check the network connection.
Carry out the update in an environment
that has little network load.
27
Mode change failure of DM860A.
D o w n l o a d
f a i l
2 7
Reset and update again.
36
Log-in to DPMS failed when Main
CPU was rewritten.
L o g i n
f a i l e d
3 6
Carry out the update in an environment
that has little network load.
37
Line, etc., is busy when logging
into DPMS when Main CPU was
rewritten.
S e r v e r
i s
b u s y 3 7
Carry out the update in an environment
that has little network load.
38
Connection to DPMS failed when
Main CPU was rewritten.
C o n n e c t i o n F a i l 3 8
Check the network connection.
Carry out the update in an environment
that has little network load.
56