background image

Cable Sizes and Fuses 

 
Cables used at each positive terminal must be of sufficient rating, under sized cables would affect the performance of the unit and 

shortens the life span. Wires connected to control or signal ports 



 carry less than 0.5 Amp. 

Fuses or circuit breakers of appropriate rating must be installed at positive terminal of the house battery and main battery. These 
fuses are for the safety and protection of the vehicle’s electrical system in case of a short to the negative ground.   
 

Using with inductive load 

 
When inductive load (such as DC motor, solenoid & etc.) is 

directly 

connected to isolator terminal, a diode (400V 3A, bundle 

with unit) must be connected across the load. 

 
1. 

General description

 

 
This advanced programmable battery protector is designed to protect all types batteries from over discharged and also safe guard 
your load . 
The limited settings of ordinary battery protector cannot cover all discharging conditions because of large combinations of battery 
type, capacity, versus types of load, size of load and loading conditions such as slow bleeding load or short large starting load such 
as high inductive or capacitive load .Unintended or unexpected "chattering" quick on-off operations, and premature or belated on 
off are the common defects which sometimes not only harmful to your valuable battery but also to the load. 
 
The reliable and efficient Mosfet switching has minimal voltage loss resulting much less generated  heat than diode based 
protectors. Microprocessor Controlled circuit provides accurate monitoring, finer tuning of voltage, delay timer set points and 
more fail safe protection with diagnostic display. 
 

2. 

Advanced Features 

 

 

Alert Voltage: 

 

The additional Alert Voltage setting is to monitor the main battery voltage even when the unit in isolated mode and when the 

 

main battery voltage drops below the set Alert Voltage, the Remote LED Module will out slow flashes to alert end user. 

 

Remote LED Module with Over-Ride 

 

With the supplied Remote LED module w Over-Ride accessory, end user is constantly informed about the status of the 

 

Protector whether it is in Connection Mode, Isolation Mode, Main Battery is above or at Alert low level and Protector is in 

 

Protection Mode. 

 

Selectable 12V or 24V system   

 

Selectable Ignition Control 

 

Wide range of programmable threshold voltages (connect, isolate, alert) with high resolution and respective delay time. 

 

Monitoring of Main battery voltage. 

 
3. 

Intended Applications: 

 
To protect starting, house or site batteries and equipment for caravan, SUV, boat, with DC loads such as DC motors, inverter, 
communication equipment, fridge, and etc. against damage, and over discharging. 
When battery is connected to a charging source such as solar, wind, battery charger, it can conserve the battery power by allowing 
the load to draw power from the charging dc source when the battery is full according to your presets of LVR and LVD. 
 

  R 

= Remote Over-ride Port for manual connection of the main and house terminal 

  A 

= Remote Alert Signal Port (System Voltage, 100mA max.) 

  Ign.  = Ignition Control Port   

  Neg. = Negative (Ground) Port   

  Main battery positive 

  Load positive 

  Control buttons 

  LED indicators (to indicate the setting status) 

  3 digits LED display  

- to display batteries voltage 

 

 

 

 

 

 

- status (ON/OFF) 

 

 

 

 

 

 

- set voltage and delay time 

 

 

 

 

 

 

- set menu 

 

 
 
 
 

Summary of Contents for SSB-6113

Page 1: ...te sparks near battery or protector during normal operation as batteries may give out explosive gas Do not use the protector if it has been dropped or damaged Do not remove casing of the protector the...

Page 2: ...nitoring finer tuning of voltage delay timer set points and more fail safe protection with diagnostic display 2 Advanced Features Alert Voltage The additional Alert Voltage setting is to monitor the m...

Page 3: ...are version to confirm setting then the battery voltage If no selection is done within 10sec unit will go back to last set system voltage Remark You have about 10 seconds to confirm your setting other...

Page 4: ...Set Mode 2 automatically after 20 seconds with the new settings N O N C Application MODE Normally Open This is the factory default mode The two terminals are normally isolated disconnected open when t...

Page 5: ...protection will lock up the unit until complete reset by disconnect and reconnect the battery Over Temperature Protection Unit Over Temperature 90 C Check location of unit is well ventilated Check cab...

Page 6: ...he spot which is powered up when the Ignition switch is on A External Alert Alarm port An external signal voltage to indicate the operation status of the unit It synchronizes with the Alert Voltage an...

Page 7: ...above control port Neg A R Black wire to Neg Negative ground Red wire to Main terminal Remote Override function Green wire to R Remote Override function Yellow wire to A LED indicator Remark If no int...

Page 8: ...n battery to Aux battery 130mV Protections System Under Voltage Disconnect Auto reconnect when condition returns to normal System Over Voltage Disconnect Auto reconnect when condition returns to norma...

Reviews: