background image

4. Use current knob to adjust current for A1, press 

current knob

 to confirm new 

setting.

5. Use  

voltage knob

 to adjust time duration in seconds for t1, press  

voltage  

knob 

to confirm new settings.

6. Repeat above steps for P2 and P3.

7. To set the number of cycles.

After t3 of P3 has been set and confirmed, the 

P icon

 will then appears and ready

for setting of number of cycles.
Adjust the

 voltage knob

 to set the number of cycles from 1 to 999***.

To double check the Timed Program Cycle Settings.

To Check the settings of Timed Presets before cycle run starts.

Just repeat procedure from 1 to 5 and take note of each setting.

To run the Timed Program cycle

Summary of Contents for NEP Series

Page 1: ...NEP SERIES User Manual REV 0 2011 08 7673 6185 0000...

Page 2: ...nels A FRONT PANEL 1 LCD display Indicates output voltage current presets CC CV status of main auxiliary outputs output On OFF running the Cycled Program and faults 2 Output Voltage Control knob Adjus...

Page 3: ...to the unit 5 Do not replace the fuse before ceasing the problems use same fuse rating 6 Never touch the power supply when your hand is wet 7 Never remove the metal cover without unplugging of AC main...

Page 4: ...e Knob then quickly press the Current Knob 1 Press the Voltage Knob and then press the Current Knob Icon 1 is flashing to show ready for setting 2 Adjust Voltage Knob for voltage value and Current Kno...

Page 5: ...ew settings and Icon 3 will start flashing to indicate Preset 3 is ready for setting 5 Adjust Voltage and Current as before and press Voltage and Current Knobs to confirm Preset 3 new settings 6 All t...

Page 6: ...cordingly 3 Repeat the above to get to Preset P2 then P3 4 Quick press of Voltage and Current Knobs at P3 will exit from the Preset Mode to normal operation mode N at which has no flashing Presets Ico...

Page 7: ...oves to the next lot of Timed Presets When the power supply is in cycle operation the cycle icon flashes with the time preset in operation Setting the Timed Presets 1 Push Button 4 to Output OFF posit...

Page 8: ...d P3 7 To set the number of cycles After t3 of P3 has been set and confirmed the P icon will then appears and ready for setting of number of cycles Adjust the voltage knob to set the number of cycles...

Page 9: ...ycle Icon is flashing This serves as a warning of wrong setting of 3 preset timers Remarks A If the number of cycle is set at zero then the unit will run infinite cycles B To exit from the Timed Prese...

Page 10: ...ent user presets 3 Programming of timer and auto cycling of preset in sequence 4 Rotary encoder tuning of V I 5 Output On Off switch with status indication 6 Large LCD display for V I Presets CC CV st...

Page 11: ...on Ripple Noise r m s Current 10mA Load Regulation 10 90 Rated Voltage 30mA Line Regulation 5 Variation 30mA Setting Accuracy 0 3 0 02 V Current Resolution 0 01A Input Voltage Input Voltage 230VAC 50H...

Page 12: ...LCD Indications Voltage and Current C C And C V Aux 1 and 2 Status Output ON OFF 3 User Defined V I Presets Running the Cycled Program Fault Indication OVP Over Voltage OCP Over Current or Load OTP Ov...

Reviews: