8.
ANALOGUE REMOTE CONTROL MODE
There are two methods for remote control of current and voltage adjustment. Both
methods require both the current and the voltage remote control to be set up together
in order to make the remote control functional. The
output on-off
is optional and will
not affect either voltage or current control.
Use the supplied 8 pin microphone plug for both method A and method B.
Remark: using the 8pin remote plug provided and connect with 22AWG wires.
8.1 Using the analogue remote control mode
Set the KPS power supply to Analogue Control Mode (AC) after all the connections with
the 8-pin metal plug is inserted at port (5) at the rear panel.
1.
Press and hold the [menu] button until display indicates setting menu mode.
2.
Rotate the VOLT knob to [UNS] menu.
3.
Press VOLT knob to enter into the UNS (Remote control interface selection).
4.
Rotate CURR knob until [AC] (Analogue Control) shows up.
5.
Press VOLT knob to confirm AC selection, the orange LED [REMOTE] lights up.
6.
KPS power supply is in Analogue Remote Control Mode.
7.
Press [menu] button to exit from setting mode. Take note of the Key Lock button
(10) & Remote LED are ON.
P.25