6.7 Ramp Up/ Ramp Down Generator
The KPS series has function to generate waveform with ramp up and ramp down.
It allow to set 10 steps of wave.
The Ramp Up/Ramp Down function can be done by both Remote Programming via USB
interface to your PC and on panel manual programming. It is recommended to use
Remote Programming for faster set up with visual wave forms and easy retrievals.
Steps to setup ramp up/ ramp down wave;
Step 1
Press and hold
to enter menu.
Step 2
Rotate Volt. knob to select dvdt menu. The display show
Step 3
Press Volt. knob to enter dvdt setting. The display show
Step 4
Rotate Volt. knob to set items
Step 5
Rotate Curr. knob to change value of set items.
The below table show the available set items and value range for dvdt
menu.
Set item
Description
Value range
Number of steps to be use for wave form
generation. Must start from step 1.
2-10
Number of cycle to run for wave form
0 to 999
0 means run forever
.....
Step 1 to Step 10 Voltage setting (in V)
0 to 36V
.....
Step 1 to Step 10 Current setting (in A)
0 to Max Current
.....
Step 1 to Step 10 run time length (in S)
0 to 600s
Step 6
Press Volt. knob to back to menu mode.
Step 7
Press
to confirm and exit menu.