7.8
Set Step 6 voltage to 7.8V
4
Set Step 6 current to 4A
5
Set Step 6 run time to 5s
(Ramp DOWN from step 6 voltage to step 7 voltage in 5s)
2.5
Set Step 7 voltage to 2.5V
9.9
Set Step 7 current to 9.9A
5
Set Step 7 run time to 5s
(Keep at 2.5V by 5s, since step 7 voltage = step 1 voltage)
6.8 Factory Reset
The Factory reset feature is reset the Preset program, UVL, UCL to factory default
setting.
Steps for Factory reset;
Step 1
Press and hold
button to enter setting menu.
Step 2
Rotate VOLT. knob to select factory reset menu. The display shows
Step 3
Press VOLT. knob to enter address menu. The display shows
Step 4
Rotate CURR knob to change from No to YES.
Step 5
Press CURR. knob to reset unit.
The power will reset immediately.