Manson Engineering Industrial KPS-6000 Series User Manual Download Page 10

5. 

INDICATORS and CONTROLS 

 

 

 

1. 

Main Power Switch 

 

 

The main power of power supply. Switch to I position to power on the power   

 

 

supply and switch to O position to power off the power supply. 

 

2. 

Volt. Meter 

 

3. 

Amp. Meter 

 

4. 

Power Indicator 

 

 

Indicate the right part 4 digits LED is watt-meter. The display is showing actual   

 

 

output Power value. 

 

5. 

Constant Voltage Mode Indicator 

 

 

Indicate the Power Supply is working in Constant Voltage mode. The output   

 

 

voltage of power supply is remains constant at the set voltage in this mode. The 

 

 

power supply will be working in this mode while the loading current is least than 

 

 

the set current. 

 

6. 

Constant Current Mode Indicator 

 

 

Indicate the Power Supply is working in Constant Current mode. The output   

 

 

current of power supply is remains constant at the set current provided that the 

 

 

loading is sufficient to draw current equal to or larger than set current. 

 

7. 

Remote Control Indicator 

 

 

Indicate the Power Supply is under remote control. Whenever you connection 

 

 

power supply using control software through USB or Ethernet or Analog remote 

 

 

control. This LED will be ON. 

 

8. 

Voltage Adjust Knob 

 

 

This knob is for output Voltage setting and UVL adjustment 

 

9. 

Current Adjust Knob 

 

 

This knob is for output Current and UCL adjustment 

P.10 

Summary of Contents for KPS-6000 Series

Page 1: ...KPS 6000 series REMOTE PROGRAMMABLE POWER SUPPLY WITH ETHERNET NETWORK CONNECTIVITY DC WAVE FORM GENERATOR 3 SELECTABLE VOLTAGE CURRENT RANGES USER MANUAL REV 2 2022 03 7673 6600 0001...

Page 2: ...urrent 12 6 2 Upper Voltage and Current Limit Adjustment 13 6 3 Select and Adjust 3 Preset Value of Voltage and Current 14 6 4 Output ON OFF Include Power up ON OFF Setting 14 6 5 Lock Unlock of Front...

Page 3: ...the original fuse 1 2 Caution Failure to observe this warning may result in damage to equipment and Improper functioning of the power supply 1 Use a grounded 3 pin AC source 2 This unit is for indoor...

Page 4: ...an optional Ethernet interface card allows users to configure control or monitor basic power supply settings over the internet KPS uses SCPI Standard Commands of Programmable Instruments syntax for ea...

Page 5: ...play 0 2 3 counts Input Voltage 90 264V 50Hz Full Load Input Current 230VAC 1 1A 1 1A 0 95A Efficiency 82 82 82 Power Factor Control 95 Cooling Method Thermostatic Control Fan From Zero to Full Speed...

Page 6: ...3 counts Input Voltage 90 264V 50Hz Full Load Input Current 230VAC 2 2A 2 2A 1 8A Efficiency 83 84 85 Power Factor Control 95 Cooling Method Thermostatic Control Fan From Zero to Full Speed Protectio...

Page 7: ...3 counts Input Voltage 180 264V 50Hz or on request Full Load Input Current 230VAC 2 6A 2 6A 2 6A Efficiency 84 85 85 Power Factor Control 95 Cooling Method Thermostatic Control Fan From Zero to Full S...

Page 8: ...counts Input Voltage 180 264V 50Hz or on request Full Load Input Current 230VAC 3 5A 3 5A 3 2A Efficiency 84 85 87 Power Factor Control 95 Cooling Method Thermostatic Control Fan From Zero to Full Sp...

Page 9: ...counts Input Voltage 180 264V 50Hz or on request Full Load Input Current 230VAC 5 0A 4 9A 4 5A Efficiency 86 5 89 87 Power Factor Control 95 Cooling Method Thermostatic Control Fan From Zero to Full...

Page 10: ...supply will be working in this mode while the loading current is least than the set current 6 Constant Current Mode Indicator Indicate the Power Supply is working in Constant Current mode The output c...

Page 11: ...ttons will be used The second function of buttons include V t A W UVL UCL 12 Output ON OFF Ramp UP DOWN Program Running Button Press this button to switch the output ON and OFF This button ON indicate...

Page 12: ...Voltage Knob clockwise to INCREASE output voltage Rotate Voltage Knob anti clockwise to REDUCE output voltage Press Voltage knob to switch between COARSE and FINE adjustment When press the knob the di...

Page 13: ...UVL adjustment Press and the button will ON Then press Voltage knob The display will show as follow Rotate Voltage knob to adjust the value Press to confirm setting If the new UVL value is lower than...

Page 14: ...re1 Pre2 Pre3 To adjust value of preset program After preset program is selected use Voltage and Current knob to adjust value for that preset program The setting will be saved automatically The value...

Page 15: ...ck of Front Panel In case the front panel is locked only the has function Other buttons and knobs are being locked The front panel will be locked in two conditions a Manually press to LOCK the front p...

Page 16: ...select dvdt menu The display show Step 3 Press Volt knob to enter dvdt setting The display show Step 4 Rotate Volt knob to set items Step 5 Rotate Curr knob to change value of set items The below tabl...

Page 17: ...tting Value Set item Value Explanation 2 Set 2 steps to run Step 1 and Step 2 3 Run 3 cycle only 2 5 Set Step 1 voltage to 2 5V 5 Set Step 1 current to 5A 3 Set Step 1 run time to 3s Ramp UP from step...

Page 18: ...p 2 6 Run 6 cycle only 2 5 Set Step 1 voltage to 2 5V 5 Set Step 1 current to 5A 3 Set Step 1 run time to 3s Ramp UP from step 1 voltage to step 2 voltage in 3s 12 Set Step 2 voltage to 12V 10 Set Ste...

Page 19: ...o step 2 voltage in 0s 12 Set Step 2 voltage to 12V 10 Set Step 2 current to 10A 3 Set Step 2 run time to 3s Keep at 12V by 3s since step 2 voltage step 3 voltage 12 Set Step 3 voltage to 12V 7 Set St...

Page 20: ...to 10A 5 Set Step 2 run time to 5s Keep at 12V by 5s since step 2 voltage step 3 voltage 12 Set Step 3 voltage to 12V 7 Set Step 3 current to 7A 4 Set Step 3 run time to 4s Ramp UP from step 3 voltag...

Page 21: ...voltage step 1 voltage 6 8 Factory Reset The Factory reset feature is reset the Preset program UVL UCL to factory default setting Steps for Factory reset Step 1 Press and hold button to enter setting...

Page 22: ...erface Step 5 Press VOLT knob to return to menu mode Step 6 Press to exit menu Please reference to software user manual for detail operation of PC control software 6 10 Change Display Brightness The K...

Page 23: ...e set from 1s to 30s Steps for changing timeout time Step 1 Press and hold button to enter setting menu Step 2 Rotate VOLT knob to select tOUt menu The display shows Step 3 Rotate VOLT knob to enter t...

Page 24: ...7 MENU FLOW P 24...

Page 25: ...ires 8 1 Using the analogue remote control mode Set the KPS power supply to Analogue Control Mode AC after all the connections with the 8 pin metal plug is inserted at port 5 at the rear panel 1 Press...

Page 26: ...Output voltage setting by remote control Check the output voltage range of the power supply by varying the external voltage source connected to Pin 2 and Pin 4 Ground Remote socket pin assignment for...

Page 27: ...in order for the remote control to be functional Remark variable resistors 5Kohm Remote socket pin assignment for variable resistor PIN FUNCTION REMARKS 1 Internal DC 5V Resistor end 2 Voltage Adjust...

Page 28: ...shows CC current setting value and the Output ON OFF Button 12 is lit off The current output voltage and current setting will show on the panel meter D You also can adjust the output by voltage curren...

Reviews: