Section 2
Installation Instructions
2-3
Electrical Service
WARNING
All wiring must conform to local, state and national
codes.
Ice Machine
Voltage Phase
Air-Cooled
Model
Cycle
Electrical Rating
QM30
230/50/1
.6 KW / 2.6 Amps
QM30
115/60/1
.6 KW/ 5.3 Amps
VOLTAGE
The maximum allowable voltage variation is
±
10%
of the rated voltage at ice machine start-up (when the
electrical load is highest).
WARNING
The ice machine must be grounded in accordance
with national and local electrical codes.
WARNING
Never use an extension cord. If an outlet is not
within reach of the ice machine’s power cord, have
a proper amperage outlet wired closer to the ice
machine.
FUSE/CIRCUIT BREAKER
A separate fuse/circuit breaker must be provided for
each ice machine.
NOTE: A means of disconnect must be provided for
field wiring.
ELECTRICAL RATING
The electrical rating is used to help select the wire
size of the electrical supply. The wire size (or gauge)
also depends on location, materials used, length of
run, etc., so it must be determined by a qualified
electrician.
FOR UNITED KINGDOM ONLY
As the colours of the wires in the mains lead of the
appliance may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows:
•
The wire which is coloured green and yellow must be
connected to the terminal in the plug which is marked
with the letter E or by the earth symbol , or
coloured green or green and yellow.
•
The wire coloured blue must be connected to the
terminal which is marked with the letter N or coloured
black.
•
The wire which is coloured brown must be connected
to the terminal which is marked with the letter L or
coloured red.