1/12
7
Electrical
GENERAL
!
Warning
All wiring must conform to local, state and national
codes.
MINIMUM CIRCUIT AMPACITY
The minimum circuit ampacity is used to help select
the wire size of the electrical supply. (Minimum circuit
ampacity is not the Blended Ice Machine’s running amp
load.) The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must
be determined by a qualifi ed electrician.
ELECTRICAL REQUIREMENTS
Refer to Blended Ice Machine Model/Serial Plate for
voltage/amperage specifi cations. A dedicated electrical
circuit is required.
MINIMUM CIRCUIT AMPERAGE CHART
Important
Due to continuous improvements, this information is
for reference only. Please refer to the serial number
tag to verify electrical data. Serial tag information
overrides information listed on this page.
Model
Numbers
Voltage/Cycle
Total
Amps
Breaker
Size
MS-8-1H,
MS-8-1LH,
MS-8-FH,
MS-8-FLH,
MS000A05,
MS000A06
115/60/1
16.0
20A
MS-8-BH
MS-8-BLH
230-240/60/1
9.8
16A
MS-8-AH,
MS-8-ALH,
MS-8-CH,
MS-8-CLH,
MS-8-EH,
MS-8-ELH,
MS000A01,
MS000A02,
MS000A03,
MS000A04
230-240/50/1
9.8
16A
GROUNDING INSTRUCTIONS
!
Warning
The machine must be grounded in accordance with
national and local electrical codes.
This appliance must be grounded. In the event of
malfunction or breakdown, grounding provides a path
of least resistance for electric current to reduce the
risk of electric shock. This appliance is equipped with
a cord having an equipment-grounding conductor
and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.
EXPORT NOTE:
For export models replace the supply
cord with a 1.5mm
2
minimum, 3 conductor H05VV-F
harmonized cord.