Reference
Only
Manitowoc
Published 09-09-16, Control # 229-09
3-25
MLC650 SERVICE/MAINTENANCE MANUAL
ELECTRICAL SYSTEM
3
PD-21
ID6
Lower Boom Point Block-Up Slow Down Switch and
Upper Boom Point Block-Up Slow Down Limit Switch
0 V
DC
Open, 24 V
DC
Closed
PD-22
IACV11
Right Strap Load Link
2 mA @ No Load
20 mA @ 238,140 kg (525,009 lb)
PD-23
IACV12
Left Strap Load Link
2 mA @ No Load
20 mA @ 238,140 kg (525,009 lb)
PD-24
IACV13
Boom-Top Angle Sensor
2 to 20 mA (90 µA/°)
PD-25
No Connection
PD-26
No Connection
PD-27
KL15
Control Module Ignition Power (from relay K6)
0 V
DC
Open, 24 V
DC
Closed
PD-28
ID9
Upper Boom Point Confirm
0 V
DC
Not Installed, 24 V
DC
Installed
PD-29
GND
Ground (from load center)
0 V
DC
PD-30
CAN1_L
CAN Bus D—Low
Not Applicable
PD-31
CAN1_H
CAN Bus D—High
Not Applicable
PD-32
No Connection
PD-33
No Connection
PD-34
IMID2
Module Identifier Input (ground from load center)
0 V
DC
PD-35
ID7
Luffing Jib Maximum Angle Limit Switch
0 V
DC
Open, 24 V
DC
Closed
PD-36
ID8
Luffing Jib Minimum Angle Limit Switch
0 V
DC
Open, 24 V
DC
Closed
PD-37
IACV14
Wind Speed Sensor
0 to 20 mA
PD-38
IACV15
Upper Boom Point/ Light Fixed Jib Left Load Pin
Sensor
0 V
DC
Open, 24 V
DC
Closed
PD-39
IACV16
Jib Butt Angle/Light Fixed Jib Right Load Pin Sensor
0 V
DC
Open, 24 V
DC
Closed
PD-40
No Connection
PD-41
No Connection
PD-42
ID10
Luffing Jib Stop Cylinder Position
0 V
DC
Not Installed, 24 V
DC
Installed
Pin
I/O Network
Function
Voltages