Table 3-16. IOLC31 Test Voltages
Pin
I/O Network
Function
Voltages
PC1-1
GND
Ground (from ground stud on rotating bed)
0 V
DC
PC1-2
KL15
Control Module Ignition Power (from engine run switch)
0 V
DC
Open, 24 V
DC
Closed
PC1-3
ID01
Not Used—For Possible Future Expansion
0 V
DC
PC1-4
ID02
Not Used—For Possible Future Expansion
0 V
DC
PC1-5
OPH6A18
Drum 0 Spool In Solenoid
0 V
DC
Off, 24 V
DC
On
PC1-6
OPH6A19
Drum 0 Spool Out Solenoid
0 V
DC
Off, 24 V
DC
On
PC1-7
OPH6A20
Not Used—For Possible Future Expansion
0 V
DC
PC1-8
OPH6A21
Not Used—For Possible Future Expansion
0 V
DC
PC1-9
No connection
PC1-10
CAN1_H
CAN Bus C—High
Not Applicable
PC1-11
+U
B
Supply Power for Control Module Outputs
24 V
DC
PC1-12
+U
E
Control Module Battery Power
24 V
DC
PC1-13
ID03
Not Used—For Possible Future Expansion
0 V
DC
PC1-14
ID04
Not Used—For Possible Future Expansion
0 V
DC
PC1-15
ID05
Not Used—For Possible Future Expansion
0 V
DC
PC1-16
ID06
Not Used—For Possible Future Expansion
0 V
DC
PC1-17
IDF15
Not Used—For Possible Future Expansion
0 V
DC
PC1-18
IMID2
Module Identifier Input (from ground stud on rotating bed)
0 V
DC
PC1-19
CAN1_L
CAN Bus C—Low
Not Applicable
PC1-20
+U
B
Supply Power for Control Module Outputs
24 V
DC
PC1-21
ID07
Not Used—For Possible Future Expansion
0 V
DC
PC1-22
ID08
Not Used—For Possible Future Expansion
0 V
DC
PC1-23
ID09
Not Used—For Possible Future Expansion
0 V
DC
PC1-24
ID10
Not Used—For Possible Future Expansion
0 V
DC
PC1-25
ID11
Not Used—For Possible Future Expansion
0 V
DC
PC1-26
IDF16
Not Used—For Possible Future Expansion
0 V
DC
PC1-27
IACV17
Drum 5 Pressure Transducer
4 mA @ 0 psi
20 mA @ 7,500 psi
PC1-28
IMID4
Module Identifier Input (from ground stud on rotating bed)
0 V
DC
PC1-29
IMID3
Module Identifier Input (from ground stud on rotating bed)
0 V
DC
PC2-1
ID12
VPC-MAX Shorting Wire
24 V
DC
PC2-2
ID13
VPC Tray Shorting Plug
24 V
DC
PC2-3
No Connection
PC2-4
IACV18
Drum 3 Pressure Transducer
0 V
DC
Off, 24 V
DC
On
Summary of Contents for MLC650
Page 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc MLC650 ...
Page 2: ...R e f e r e n c e O n l y ...
Page 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Page 375: ...R e f e r e n c e O n l y ...
Page 376: ...R e f e r e n c e O n l y ...