Reference
Only
Manitowoc
Published 09-09-16, Control # 229-09
10-67
MLC650 SERVICE/MAINTENANCE MANUAL
ACCESSORIES
10
10
ACTIVE FIXED MAST STOP SYSTEM
General
This part of Section 10 provides the electrical and hydraulic
control of the active fixed mast stop (AFMS) system.
Additional component information for this system can be
found in the following sections of the Service Manual:
•
Section 2: Hydraulics
•
Section 3: Electrical
See
for an illustration of the active fixed mast
stop.
See
for the hydraulic schematic of the AFMS
system circuit.
See
for the electrical schematic of the AFMS
system circuit.
The AFMS system consists of two fixed mast stops, each
containing an integral hydraulic cylinder. The AFMS system
controls the pressure within the mast stop cylinders over the
operational range of the cylinder as well as adapts to current
crane conditions.
Each mast stop cylinder contains the following internal
components:
•
Hydraulic accumulator
•
Pressure relief valve with bypass check valve
•
Rupture disc
Each mast stop also uses the following (see
):
•
Mast cylinder pressure transducer (1)
•
Mast cylinder pressure-reducing solenoid valve (2)
•
Mast cylinder directional control solenoid valve (3)
•
Direct acting relief valve
Item
Description
1
Mast Cylinder Pressure Transducer
2
Mast Cylinder Pressure-Reducing Solenoid Valve
3
Mast Cylinder Directional Control Solenoid Valve
4
Mast Stop with Integral Hydraulic Cylinder
FIGURE 10-54