PC2-15
ODH31A01
Power Bus:
•
VPC-MAX Tray Maximum In
•
VPC-MAX Tray Maximum Out
•
VPC-MAX Beam Level Sensor
0 V
DC
Open, 24 V
DC
Closed
PC2-16
No Connection
PC2-17
ODH3A09
Beam/Foot Upper Pin Extend
0 V
DC
Off, 24 V
DC
On
PC2-18
OPH3A14
Not Used—For Possible Future Expansion
0 V
DC
PC2-19
OPH3A17
Not Used—For Possible Future Expansion
0 V
DC
PC2-20
+U
B
Supply Power for Control Module Outputs
24 V
DC
PC2-21
No Connection
PC2-22
IACV21
VPC-MAX Beam Level Sensor (pitch)
5.025 V
DC
@ 0°
±
1.005 V
DC
Offset/°
PC2-23
IACV22
VPC-MAX Beam Level Sensor (roll)
5.025 V
DC
@ 0°
±
1.005 V
DC
Offset/°
PC2-24
ODH3A03
VPC Actuator Pin Retract
0 V
DC
Off, 24 V
DC
On
PC2-25
No Connection
PC2-26
ODH3A08
VPC-MAX Actuator Encoder
0 V
DC
Off, 24 V
DC
On
PC2-27
ODH3A11
Beam/Foot Lower Pin Extend
0 V
DC
Off, 24 V
DC
On
PC2-28
ODH3A13
Not Used—For Possible Future Expansion
0 V
DC
PC2-29
ODH3A16
Not Used—For Possible Future Expansion
0 V
DC
Pin
I/O Network
Function
Voltages