![Manitowoc MLC650 Service Maintenance Manual Download Page 111](http://html.mh-extra.com/html/manitowoc/mlc650/mlc650_service-maintenance-manual_701260111.webp)
Reference
Only
Manitowoc
Published 09-09-16, Control # 229-09
3-49
MLC650 SERVICE/MAINTENANCE MANUAL
ELECTRICAL SYSTEM
3
Table 3-20. IOLC35 Test Voltages
PC2-6
ODH3A04
Not Used—For Possible Future Expansion
0 V
DC
PC2-7
ODH3A07
Not Used—For Possible Future Expansion
0 V
DC
PC2-8
ODH3A10
Not Used—For Possible Future Expansion
0 V
DC
PC2-9
ODH3A12
Not Used—For Possible Future Expansion
0 V
DC
PC2-10
OPH3A15
Drum 4 Left Motor Control
0 V
DC
Open, 24 V
DC
Closed
PC2-11
+U
B
Supply Power for Control Module Outputs
24 V
DC
PC2-12
OS85H
Not Used—For Possible Future Expansion
0 V
DC
PC2-13
IACV19
Not Used—For Possible Future Expansion
0 V
DC
PC2-14
IACV20
Not Used—For Possible Future Expansion
0 V
DC
PC2-15
ODH3A01
Not Used—For Possible Future Expansion
0 V
DC
PC2-16
ODH3A06
Not Used—For Possible Future Expansion
0 V
DC
PC2-17
ODH3A09
Not Used—For Possible Future Expansion
0 V
DC
PC2-18
OPH3A14
Pump 9 Variable Displacement
0 V
DC
Off, 24 V
DC
On
PC2-19
OPH3A17
Cooler Fan Pump Solenoid
0 V
DC
Off, 24 V
DC
On
PC2-20
+U
B
Supply Power for Control Module Outputs
24 V
DC
PC2-21
OS85L
Not Used—For Possible Future Expansion
0 V
DC
PC2-22
IACV21
VPC-MAX Beam Max Out
24 V
DC
PC2-23
IACV22
Not Used—For Possible Future Expansion
0 V
DC
PC2-24
ODH3A03
Not Used—For Possible Future Expansion
0 V
DC
PC2-25
ODH3A05
Not Used—For Possible Future Expansion
0 V
DC
PC2-26
ODH3A08
Not Used—For Possible Future Expansion
0 V
DC
PC2-27
ODH3A11
Not Used—For Possible Future Expansion
0 V
DC
PC2-28
ODH3A13
Not Used—For Possible Future Expansion
0 V
DC
PC2-29
ODH3A16
Drum 4 Right Side Motor Control
0 V
DC
Off, 24 V
DC
On
Pin
I/O Network
Function
Voltages
Pin
I/O Network
Function
Voltages
PC1-1
GND
Ground (from ground stud on rotating bed)
0 V
DC
PC1-2
KL15
Control Module Ignition Power (from relay K6)
0 V
DC
Open, 24 V
DC
Closed
PC1-3
ID01
VPC-MAX Tray Max Out
0 V
DC
Open, 24 V
DC
Closed
PC1-4
ID02
VPC-MAX Tray Max In
0 V
DC
Open, 24 V
DC
Closed
PC1-5
OPH6A18
Not Used—For Possible Future Expansion
0 V
DC
PC1-6
OPH6A19
Not Used—For Possible Future Expansion
0 V
DC
PC1-7
OPH6A20
Not Used—For Possible Future Expansion
0 V
DC
PC1-8
OPH6A21
Not Used—For Possible Future Expansion
0 V
DC