![Manitowoc Grove GRT8120 Operator'S Manual Download Page 298](http://html.mh-extra.com/html/manitowoc/grove-grt8120/grove-grt8120_operators-manual_701202298.webp)
OPERATING PROCEDURES
GRT8120 OPERATOR MANUAL
4-168
Published 3-22-2021, Control # 702-02
The Current Swing Angle
Shows the swing angle (1, Figure 4-198) of the current
superstructure position.
0° means that the superstructure is positioned over the front.
A full turn from this working position is divided into two
semi-circles (Figure 4-199).
Angles in the left semi-circle are displayed as negative
values (0° to -179.9°),
Angles in the right semicircle will be shown as positive (0° to
180°).
Currently Raised Load
The display (Figure 4-200) shows the sum of the p
lifting gear + hook block.
Maximum Load
The display (Figure 4-201) shows the maximum load that
can be lifted in the current rigging mode with the current
working radius.
Degree of Utilization
The degree of utilization shows the weight of the current load
as a percentage of the maximum possible load. Display (2,
Figure 4-202) shows the percentage value. Display (1)
shows the ranges in different colors:
10254-54a
FIGURE 4-198
1
FIGURE 4-199
10083
Green:
0 – 90%
Yellow:
approx. 90 – 100%
Red:
greater than 100%
9082-2a
FIGURE 4-200
1.75
9082-2a
FIGURE4-201
1.75
9082-2
FIGURE4-202
2
1
1.75
Summary of Contents for Grove GRT8120
Page 1: ...Operator Manual Grove GRT8120 ...
Page 4: ...THIS PAGE BLANK ...
Page 16: ...TABLE OF CONTENTS GRT8120 A 12 THIS PAGE BLANK ...
Page 24: ...INTRODUCTION GRT8120 OPERATOR MANUAL 1 8 Published 3 22 2021 Control 702 02 THIS PAGE BLANK ...
Page 440: ...GRT8120 OPERATOR MANUAL A 10 Published 3 22 2021 Control 702 02 THIS PAGE BLANK ...
Page 447: ......
Page 448: ......