OPERATING CONTROLS AND PROCEDURES
5540F/YB5515 OPERATOR’S MANUAL
3-32
Published 10-21-2011, Control # 055-03
Unattended Crane
The configuration in which the crane should be left while
unattended shall be determined by a qualified, designated
individual familiar with the job site, configuration, conditions,
and limitations
Towing A Disabled Machine
If the crane becomes disabled and can not be moved under
engine power, the crane may be towed for a distance of one
mile (1.5 km) by another piece of equipment, which is
designed for towing. Always use a rigid tow bar and ensure
that the travel select lever and the transmission are in
Neutral (N). Restrict the travel to 15 mph (25 kmph).
If it is necessary to tow the crane for a distance in excess of
one mile (1.5 km), the drive shafts must be disconnected to
inhibit damage to the transmission system.
WARNING
Tipping Hazard!
Changing weather conditions including but not limited to:
wind, ice accumulation, precipitation, flooding, lightning,
etc. should be considered when determining the location
and configuration of a crane when it is to be left
unattended.
Failure to comply with these instructions may cause death
or serious injury.