Installation Instructions

 

 

Section 1

 

 

Dimensions 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 

 

Condenser Water 

Inlet

 

Condenser Water 

Outlet

 

Potable Water Inlet

 

Drain

 

Electrical

 

MODEL  H W D 1 6 2  7  4  9 5 

10 3 8 

MM 

635 343  420 NA  NA NA  NA  63.5  88.9 50.8 140 76.2 38.1 

EC018 

INCH 

25.0 

13.5 16.5 NA NA NA NA  2.5  3.5 2.0 5.5 3.0 1.5 

MM 

650 450  475 100.5 53.4 45.5 138.4 125.5 118.4 

45.3 225 125.5 

183.4

EC020 

EC030

 

INCH 

25.59 

17.72 18.7 3.96  2.1  1.79  5.45  4.94  4.66 1.78 8.86 4.94 7.22 

MM 

800 550  550 108 77.5  68  123  87.5  221  68 275 108 168 

EC040 

EC050 

INCH 

31.5 21.65 21.65 4.25  3.05  2.68  4.82  3.44  8.71  2.68 10.83 4.25  6.59 

MM 

902  700  600  114.3  82.6  76.2  120.7  95.25  222.25 82.6 279.4 120.7 171.5

EC065 

EC080

 

INCH 

35.5 27.5 23.5  4.5  3.25  3.0  4.75  3.75  8.75 3.25 11.0 4.75 6.75 

 

D

1

2

4

 

5

 

3

6

 

7

 

8

 

9

 

10

 

152.4 mm 
(6 in) 

ELECTRICAL 

DRAIN

POTABLE WATER 

INLET 

WATER COOLED 

CONDENSER INLET 

WATER COOLED 

CONDENSER OUTLET

Summary of Contents for ECG018A

Page 1: ...Y POTENTIAL Do not operate equipment that has been misused abused neglected damaged or altered modified from that of original manufactured specifications Model Numbers This manual covers the following models Self Contained Air Cooled Self Contained Water Cooled ECS018A Not Available ECG018A Not Available ECS020A Not Available ECG020A Not Available ECS030A Not Available ECG030A Not Available ECS040...

Page 2: ...tions Self Contained Air Cooled Self Contained Water Cooled Top Sides 203 mm 8 in 127 mm 5 in Back 127 mm 5 in 127 mm 5 in NOTE The ice machine may be built into a cabinet There is no minimum clearance requirement for the top or left and right sides of the ice machine The listed values are recommended for efficient operation and servicing only CAUTION The ice machine must be protected if it will b...

Page 3: ...e wire size or gauge is also dependent upon location materials used length of run etc This must be determined by a qualified electrician Air Cooled Water Cooled Ice Machine Maximum Fuse Circuit Breaker Total Amps KW Maximum Fuse Circuit Breaker Total Amps KW 230 1 50 10 Amp 2 2 506 N A N A N A EC018 EC020 without a Timer 230 1 60 10 Amp 2 2 506 N A N A N A 230 1 50 10 Amp 2 5 575 10 Amp 2 3 529 EC...

Page 4: ...hese guidelines when installing drain lines to prevent drain water from flowing back into the ice machine and storage bin Drain lines must have a 3 8 cm 1 5 inch drop of run for each meter 3 feet and must not create traps The floor drain must be large enough to accommodate drainage from all drains Run separate bin and water cooled condenser drain lines Insulate them to prevent condensation WATER S...

Page 5: ... 45 3 225 125 5 183 4 EC020 EC030 INCH 25 59 17 72 18 7 3 96 2 1 1 79 5 45 4 94 4 66 1 78 8 86 4 94 7 22 MM 800 550 550 108 77 5 68 123 87 5 221 68 275 108 168 EC040 EC050 INCH 31 5 21 65 21 65 4 25 3 05 2 68 4 82 3 44 8 71 2 68 10 83 4 25 6 59 MM 902 700 600 114 3 82 6 76 2 120 7 95 25 222 25 82 6 279 4 120 7 171 5 EC065 EC080 INCH 35 5 27 5 23 5 4 5 3 25 3 0 4 75 3 75 8 75 3 25 11 0 4 75 6 75 D ...

Page 6: ...lines and moving equipment Has the owner operator been instructed regarding maintenance and the use of Manitowoc Cleaner and Sanitizer Has the owner operator completed the warranty registration card Has the ice machine and bin been sanitized Has this manual been given to the owner operator Is the ice off wash switch set to the ice position Before Starting the Ice Machine All ice machines are facto...

Reviews: