1-4 

Installation Instructions

 

Section 1

Water Service/Drains 

WATER SUPPLY 

Local water conditions may require treatment of the water to 
inhibit scale formation, filter sediment, remove chlorine, and 
improve taste and clarity. 
 

WATER INLET LINES 

Follow these guidelines to install water inlet lines: 

 

Do not connect the ice machine to a hot water supply. Be 
sure all hot water restrictors installed for other equipment are 
working. (Check valves on sink faucets, dishwashers, etc.) 

 

Water pressure to the machine should be between 1.4 to 5.5 
bar (20 to 80 psi). 

 

If water pressure exceeds the maximum 5 bar recommended 
pressure, obtain a water pressure regulator from your 
Manitowoc distributor. Adjust pressure to 2.5 bar (37 psi). 

 

Install a water shut-off valve. 

 

Connect to a potable water supply only. 

 
 

Important

 

If you are installing a water filter system, make sure that 
you use a separate line for water-cooled condenser. 
Filter life will be greatly reduced if filtered water is used 
for water-cooled condenser.  

 

DRAIN CONNECTIONS 

Follow these guidelines when installing drain lines to prevent 
drain water from flowing back into the ice machine and storage 
bin: 

 

Drain lines must have a 3.8 cm (1.5 inch) drop of run for 
each meter (3 feet), and must not create traps. 

 

The floor drain must be large enough to accommodate 
drainage from all drains. 

 

Run separate bin and water-cooled condenser drain lines. 
Insulate them to prevent condensation

 
 
 
 

 

WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS 

 Water 

Temperature 

Water 

Pressure 

Ice Machine 

Fitting 

Tubing Size Up to Ice 

Machine Fitting 

*Ice Making 

Water Inlet 

10ºC (50ºF) Min. 

40ºC (104ºF) Max. 

1.4 Bar (20 Psi) Min. 

5.5 Bar (80 Psi) Max 

3/4”

 

Male Pipe 

Thread 

15mm (1/2”) Inside 

Diameter Minimum 

**Drain Connection 

Outlet 

----- 

----- 

7/8” Barb connection 

18mm (3/4”) Minimum   

Inside Diameter 

Condenser Water Inlet 

0.6ºC (33ºF) Min. 

32.2ºC (90ºF) Max. 

1.4 Bar (20 Psi) Min. 

10.3 Bar (150 Psi) Max 

3/8” Female pipe  

Thread 

15mm (1/2”) Inside 
Diameter Minimum 

Condenser Water Outlet 

----- 

----- 

1/2” Female pipe  

Thread 

15mm (1/2”) Minimum    
Inside Diameter  

 
 

* Water inlet hose supplied with machine. 

3/4” Female Pipe Thread/ 2 meters long. 

 

** Drain hose supplied with machine. 

7/8” (22.2mm) hose/ 2 meters long. 

 

ELECTRICAL 

DRAIN 

POTABLE WATER 

INLET 

WATER COOLED 

CONDENSER INLET 

WATER COOLED 

CONDENSER OUTLET 

Summary of Contents for ECG018A

Page 1: ...Y POTENTIAL Do not operate equipment that has been misused abused neglected damaged or altered modified from that of original manufactured specifications Model Numbers This manual covers the following models Self Contained Air Cooled Self Contained Water Cooled ECS018A Not Available ECG018A Not Available ECS020A Not Available ECG020A Not Available ECS030A Not Available ECG030A Not Available ECS040...

Page 2: ...tions Self Contained Air Cooled Self Contained Water Cooled Top Sides 203 mm 8 in 127 mm 5 in Back 127 mm 5 in 127 mm 5 in NOTE The ice machine may be built into a cabinet There is no minimum clearance requirement for the top or left and right sides of the ice machine The listed values are recommended for efficient operation and servicing only CAUTION The ice machine must be protected if it will b...

Page 3: ...e wire size or gauge is also dependent upon location materials used length of run etc This must be determined by a qualified electrician Air Cooled Water Cooled Ice Machine Maximum Fuse Circuit Breaker Total Amps KW Maximum Fuse Circuit Breaker Total Amps KW 230 1 50 10 Amp 2 2 506 N A N A N A EC018 EC020 without a Timer 230 1 60 10 Amp 2 2 506 N A N A N A 230 1 50 10 Amp 2 5 575 10 Amp 2 3 529 EC...

Page 4: ...hese guidelines when installing drain lines to prevent drain water from flowing back into the ice machine and storage bin Drain lines must have a 3 8 cm 1 5 inch drop of run for each meter 3 feet and must not create traps The floor drain must be large enough to accommodate drainage from all drains Run separate bin and water cooled condenser drain lines Insulate them to prevent condensation WATER S...

Page 5: ... 45 3 225 125 5 183 4 EC020 EC030 INCH 25 59 17 72 18 7 3 96 2 1 1 79 5 45 4 94 4 66 1 78 8 86 4 94 7 22 MM 800 550 550 108 77 5 68 123 87 5 221 68 275 108 168 EC040 EC050 INCH 31 5 21 65 21 65 4 25 3 05 2 68 4 82 3 44 8 71 2 68 10 83 4 25 6 59 MM 902 700 600 114 3 82 6 76 2 120 7 95 25 222 25 82 6 279 4 120 7 171 5 EC065 EC080 INCH 35 5 27 5 23 5 4 5 3 25 3 0 4 75 3 75 8 75 3 25 11 0 4 75 6 75 D ...

Page 6: ...lines and moving equipment Has the owner operator been instructed regarding maintenance and the use of Manitowoc Cleaner and Sanitizer Has the owner operator completed the warranty registration card Has the ice machine and bin been sanitized Has this manual been given to the owner operator Is the ice off wash switch set to the ice position Before Starting the Ice Machine All ice machines are facto...

Reviews: