C19 - OVERLOAD
CHECK
- The overload must activate at between 1.1 and 1.2 times the nominal load (see CHAPTER 2 - General characteristics).
Expected result:
• 280 TJ Nominal load 240 Kg: activation load between 264 kg and 288 kg
• 280 TJ Nominal load 350 Kg: activation load between 385 kg and 420 kg
• 260 TJ Nominal load 400 Kg: activation load between 440 kg and 480 kg
- The overload sensors must activate at the same time.
Refer to the repair manual for information about adjusting the overload
In the case of malfunction, forbid usage of the nacelle. Consult your dealership.
C20 - STOPPING DISTANCE
CHECK
S
TOPPING
DISTANCE
ON
HORIZONTAL
GROUND
:
- The stopping distance is tested on flat ground with 1.1 times the nominal load in the basket.
- Reach maximum speed and then release the control.
Expected result:
On horizontal ground
Stopping distance
Transport speed
1 400 mm +or- 300 mm
Working speed
160 mm +or- 50 mm
C
HECK
BRAKE
HOLDING
ON
A
SLOPE
- Place the nacelle on a nominal 25% slope static with 1.1 times the nominal load in the basket.
Expected result: no slipping of the nacelle must be detected after one minute.
647382 EN (01/02/2015)
Summary of Contents for 260 TJ
Page 4: ...FRONT REAR 260 TJ 280 TJ 647382 EN 01 02 2015...
Page 6: ...1 2 647382 EN 01 02 2015...
Page 25: ...1 21 647382 EN 01 02 2015...
Page 40: ...1 36 647382 EN 01 02 2015...
Page 41: ...2 1 2 DESCRIPTION 2 DESCRIPTION 647382 EN 01 02 2015...
Page 42: ...2 2 647382 EN 01 02 2015...
Page 73: ...2 33 647382 EN 01 02 2015...
Page 92: ...2 52 647382 EN 01 02 2015...
Page 94: ...2 54 647382 EN 01 02 2015...
Page 95: ...3 1 3 MAINTENANCE 3 MAINTENANCE 647382 EN 01 02 2015...
Page 96: ...3 2 647382 EN 01 02 2015...
Page 135: ...4 1 4 ELECTRICITY 4 ELECTRICITY 647382 EN 01 02 2015...
Page 136: ...4 2 647382 EN 01 02 2015...
Page 138: ...4 4 647382 EN 01 02 2015...