18
8.4
Optional Accessory Connections
NOTICE
•
Photo cells must be installed facing each other across the door's path within 6” (15 cm) of the plane of
the door and the beam no more than 5-3/4” (14,6 cm) above the floor.
•
Keep low voltage wires separate from line voltage wires.
•
Use copper conductors only.
8.4.1
Electric Photo Cells / Photo Eyes (Non-Monitored)
Through Beam Type
Figure 25 - PHOTO 008
Figure 26 - PHOTO 015 / 016 / 045 / 050 / 051 / 059
Reflective Type
Figure 27 - PHOTO 018
Figure 28 - PHOTO 038
Figure 29 - PHOTO 060
For technical support, please call
1-800-361-2260
for more information