11 Electromechanical Circuit Programming (Contactor Circuit)
WARNING
To reduce risk of SEVERE INJURY or DEATH to persons:
•
Manaras-Opera strongly recommends the use of external entrapment protection devices, especially in
the case of momentary contact to close (B2 wiring or Timer to Close).
11.1 Run Mode Settings
NOTICE
•
Always return the door to
fully closed position
before performing any program settings.
Mode
Functions
Operations
C2
•
Momentary contact to open and stop,
constant-pressure-to-close with 3-button
station.
•
Activation of safety devices will reverse the
door while closing.
•
Auxiliary devices function as an Open control
and will reverse the door while closing.
B2 Mode → C2 Mode
Move
RED
wire from
terminal
#7 →
#5
.
B2
•
Momentary contact to open, close and stop
with 3-button station.
•
Activation of safety devices will reverse the
door while closing.
•
Auxiliary devices function as an Open/Close
control and will reverse the door while
closing.
C2 Mode → B2 Mode
Move
RED
wire from
terminal
#5 →
#7
.
For technical support, please call
1-800-361-2260
for more information