Operating Cycles
The Device has three Wash Cycle Options – Eco/Normal/Intense
Eco – Light Wash Cycle
1.
Cold Rinse/Hot Wash
2 Min
2.
Hot Rinse/Disinfection
(Disinfection Parameters Set)
3.
Cool down
20 Sec
Normal – Standard Wash Cycle
1.
Cold Rinse
2 Min
2.
Hot Wash
2 Min
3.
Hot Rinse/Disinfection
(Disinfection Parameters Set)
4.
Cool down
20 Sec
Intense – Heavy Wash
1.
Cold Rinse
2 Min
2.
Hot Wash
2 Min
3.
Hot Rinse
2 Min
4.
Disinfection
(Disinfection Parameters Set)
5.
Cool down
20 Sec
Note:
These times are only the Stage specific holding times and do not include filling, heating or draining.
Wash Stages
Wash cycles are comprised of the following stages:
Cold Rinse
:
Initial Rinse using water below 45°C
Hot Wash
:
Hot Wash at 50°C with the addition of detergent
Hot Rinse
:
Hot Water Rinse
Disinfection
:
Disinfection Wash as per set disinfection parameters (Factory 1 minute @ 90°C)
Cool Rinse
:
Final Rinse to cool processed items below 75°C
1.2
Chemical Dosing System
The chemical dosing system ensures the correct amount of process chemicals are delivered at the correct stage during
each operating cycle. Chemical addition is controlled by the automatic cycle controller and an alarm if the incorrect
amount of chemical is injected. The dosing system is designed for use with Malmet Chemical; other chemicals may impair
the operation of the system.