TROUBLESHOOTING
Before you send out the heater for repairing please check the following points first, they are not faults:
Problem
Cause
Smell, smoke or sparking when using first time.
This is quite normal and is caused by dust. It will soon
stop.
Emission of white smoke, abnormal noise and/or
smell when using for first time, or after fuel stop.
Air in the fuel line. This will cease when the air is
pressed out.
Strange sound when igniting or after extinguishing
The metal parts on the machine expand/contract.
This is quite normal.
Flames or sparks through the outlet during ignition.
Fuel left in the oil line, which produces unsuitable
fuel/air mixture and therefore irregular combustion.
Sparks are caused by fragments of soot. This is quite
normal.
Problem
Machine
will not
start
Flame does
not ignite
Flame ex-
tinguishes
Fuel
leak
Smoke
or dust
Flames
from
outlet
Action
No power
supply
•
Make sure power cord
is plugged in.
Power
failure
•
Try again when power
returns.
Low volt-
age
•
•
Rectify problem caus-
ing low voltage.
Incorrect
mains fre-
quency
•
•
Only connect to power
supply with frequency
specified on type plate.
Clogged air
hole
•
Clean hole in fuel tank
cap.
Clogged
filter
•
•
•
Check and replace filter
if necessary.
Fuel short-
age
•
Fill up with fuel.
Water in
fuel
•
•
•
Empty and clean fuel
tank.
Poor fuel
quality
•
•
Empty and clean tank,
and refill with suitable
fuel.
Fuel drain
screw not
correctly
tightened
•
Tighten the screw