4
ENGLISH (Original instructions)
Explanation of general view
1-1. Base
1-2. Bolt holes
2-1. Switch trigger
2-2. Lock-off button
3-1. Spark guard
3-2. Screwdriver
4-1. Guide plate
4-2. Move
4-3. Socket wrench
4-4. Hex bolts
6-1. Guide plate
6-2. Socket wrench
6-3. Hex bolts
7-1. Clamping screw
10-1. Shaft lock
10-2. Socket wrench
10-3. Cut-off wheel
10-4. Loosen
10-5. Tighten
11-1. O-ring
11-2. Inner flange
11-3. Ring
11-4. Spindle
11-5. Cut-off wheel
11-6. Outer flange
11-7. Hex bolt
12-1. Vise plate
12-2. Vise nut
12-3. Vise handle
13-1. Spacer block
14-1. Guide plate
14-2. Straight piece of wood (Spacer)
14-3. Over 85mm long
15-1. Diameter of workpiece
15-2. Guide plate
15-3. Spacer block
15-4. Width of spacer block
15-5. Vise plate
16-1. Blocks
18-1. Limit mark
19-1. Screwdriver
19-2. Brush holder cap
SPECIFICATIONS
Model MT242
Wheel diameter
355 mm
Hole diameter
25.4 mm
No load speed (min
-1
) 3,800
Dimensions (L x W x H)
500 mm x 280 mm x 640 mm
Net weight
17.8 kg
Safety class
/II
• Due to our continuing program of research and development, the specifications herein are subject to change without notice.
• Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
ENE007-3
Intended use
The tool is intended for cutting in ferrous materials with
appropriate abrasive cut-off wheel. Follow all laws and
regulations regarding dust and work area health and
safety in your country.
ENF002-2
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
ENF100-1
For public low-voltage distribution systems of
between 220 V and 250 V.
Switching operations of electric apparatus cause
voltage fluctuations. The operation of this device under
unfavorable mains conditions can have adverse effects
to the operation of other equipment. With a mains
impedance equal or less than 0.28 Ohms it can be
presumed that there will be no negative effects. The
mains socket used for this device must be protected
with a fuse or protective circuit breaker having slow
tripping characteristics.
ENG905-1
Noise
The typical A-weighted noise level determined
according to EN61029:
Sound pressure level (L
pA
) : 103 dB(A)
Sound power level (L
WA
) : 112 dB(A)
Uncertainty (K) : 3 dB(A)
Wear ear protection
ENG900-1
Vibration
The vibration total value (tri-axial vector sum)
determined according to EN61029:
Vibration emission (a
h
) : 3.5 m/s
2
Uncertainty (K) : 1.5 m/s
2
ENG901-1
•
The declared vibration emission value has been
measured in accordance with the standard test
method and may be used for comparing one tool
with another.
•
The declared vibration emission value may also be
used in a preliminary assessment of exposure.
Summary of Contents for MT242
Page 11: ...11 13 14 15 16 17 18 19 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 0 170 35 205 70 240...
Page 13: ...13 355 115 119 115 106 102 194 70 233 137 115 103 100 012060 Fig 17 Fig 18 Fig 19...
Page 45: ...45...
Page 46: ...46...
Page 47: ...47...
Page 48: ...48 Makita Corporation Anjo Aichi Japan www makita com 885154 975...