![background image](http://html.mh-extra.com/html/makita/maktec-mt813/maktec-mt813_technical-information_1722627007.webp)
W
iring diagram
P 7 / 9
[1] Wiring of Field Lead Wires
Route the field lead wires as illustrated below in Fig. 11 before mounting brush holder.
Rib B
Rib A
Rib C
Rib F
Field lead wire (black) to
No.1a terminal on switch
Field lead wire (red) to
the No.3 terminal on switch
Field lead wire (black) to
the No.2a terminal on switch
Route between rib A and rib B.
Route between rib D and
rib E.
Route between rib E and rib F.
Noise suppressor
Put noise suppressor in this position if used.
Rib E
Rib D
Boss A
Be careful not to pinch the following
lead wires between boss A and
handle cover:
*Field lead wire (white) to the No.4
terminal on switch
*Field lead wire (red) to the No.6
terminal on switch
Fig. 11
Field lead wire (white) to the No.4 terminal on switch
Route this wire between rib B and rib C, and ensure that
it is tight between rib C and motor field in order to avoid
accidental contact with commutator.