W
iring diagram
P 18 /20
Housing cover
Motor housing
Terminal block
Insulated connector
Soft start circuit
Lead holder
Lead wire of
soft start circuit
Lead wire of soft start
circuit has to be held
with the lead holder.
Punched hole
Do not push insulated connector
into motor housing through the
punched hole.
under Housing Cover
Motor housing
Varnish tetron
tube
Varnish tetron
tube
Rib
Field
The lead wires which are put
on the edge of field, have to
be bundled with varnish tetron
tubes by separating in two groups.
And max. four lead wires have to
be in each bundle.