R
epair
P 5 / 11
< 3 > Replacement of motor housing
Brush holder
cap
Carbon brush
1. Detach carbon brushes, pan head screw M5 and hex lock nut M5x8 which fasten motor housing
on angular guide, as illustrated in Fig. 4.
Pan head screw M5
Hex lock nut M5x8
Fig. 4
Angular
guide
Blade case unit
Armature
Pan head
screws M5x50
Motor housing
2. Motor housing can be separated from blade case unit by removing 3 pan head screws M5x50
as illustrated in Fig. 5.
Fig. 5