R
epair
P 4 / 11
< 2 > Replacement of motor and blade case
1. Detach carbon brushes and remove 2 counter sunk head screws M4x8 which fasten depth guide on base
as illustrated in Fig.2.
2.Blade case unit can be separated from motor housing by unscrewing 3 pan head screws M5x50
as illustrated in Fig. 3.
Countersunk
head screw M4x8
Brush holder cap
Carbon brush
Depth guide
Base.
Fig. 2
Blade case unit
Armature
Pan head
screws M5x50
Motor housing
Fig. 3
< Note > Pay attention not to lose compression spring 5 of shaft lock, when removing armature