background image

R

epair

P 8 / 11  

4. Remove E-ring 3. Then, screw M5x12 and stopper pin which fasten dial on angular plate, can be removed
    as illustrated in Fig. 12.

E-ring 3

Stopper pin

Screw M5x12

Dial for 45° bevel stop  

5. Remove screw M5x12 from angular plate, then shoulder pin 6-2 and angular guide can be separated
    from angular plate as illustrated in Fig. 13.

Fig. 12

Screw M5x12

Shoulder pin 6-2

Angular guide

Fig. 13

< 6 > Replacement of bearing box

1. Remove retaining ring 42 and tension spring 4 from blade case. And detach safety cover as illustrated
    in Fig. 14.

Retaining ring 42

Tension spring 4 

Safety cover

Depth guide

Fig. 14

Summary of Contents for 5007NH

Page 1: ...be used under DC 120V produced by generator too Of course they take over all features of 5007NB such as well balanced body Their variations are as follows 15 0 7 0 50 60 AC DC 1 600 1 600 900 900 2 0...

Page 2: ...alloyed metal Equipped with carbide tipped saw blade with 24T only for North American market Bevel angle adjust lever is equipped with rubber cap for easy and comfortable operation Easy replaceable ba...

Page 3: ...2 3 8 44 5 1 3 4 60 3 2 3 8 46 0 1 13 16 42 9 1 11 16 61 9 2 7 16 47 6 1 7 8 44 5 1 3 4 58 7 2 5 16 46 0 1 1 16 Material of blade case Material of base Magnesium Magnesium die cast Magnesium Aluminum...

Page 4: ...g 2 2 Blade case unit can be separated from motor housing by unscrewing 3 pan head screws M5x50 as illustrated in Fig 3 Countersunk head screw M4x8 Brush holder cap Carbon brush Depth guide Base Fig 2...

Page 5: ...ex lock nut M5x8 which fasten motor housing on angular guide as illustrated in Fig 4 Pan head screw M5 Hex lock nut M5x8 Fig 4 Angular guide Blade case unit Armature Pan head screws M5x50 Motor housin...

Page 6: ...w M4x8 Lock plate Lever plate Flat washer 8 Flat washer 12 2 Remove pan head screw M4x8 lever plate lock plate hex nut M8 flat washer 8 and flat washer 12 as illustrated in Fig 7 3 Remove 2 countersun...

Page 7: ...M5x12 which fasten angular plate to the base 2 So angular plate can be separated from base together with angular guide as illustrated in Fig 10 Fig 10 Angular plate Angular guide 3 Remove pan head scr...

Page 8: ...ove screw M5x12 from angular plate then shoulder pin 6 2 and angular guide can be separated from angular plate as illustrated in Fig 13 Fig 12 Screw M5x12 Shoulder pin 6 2 Angular guide Fig 13 6 Repla...

Page 9: ...r 39 Ring 15 Retaining ring R 3 Ball bearing 6002DDW Spindle Bearing box Note O ring 46 has to be attached into the groove of bearing box before assembling bearing box 7 Adjusting accuracy of 90 cut A...

Page 10: ...some countries Note Noise suppressor is not used in some countries Put polyolefin tube on terminal for connection to terminal 2 of switch 1 Insert lead wire for connection to terminal 2 into polyolef...

Page 11: ...sing Press lead wire of field into the bottom of lead holder Noise suppressor if use Model 5007NL Blade Left type Noise suppressor if use Do not loosen lead wire of field inside motor housing Press le...