10
Version: 1.05, 05.10.18
DMX-
Rate
BREAK
LENGTH
MAB
MARK AFTER
BREAK
MBS
MARK BETWEEN
SLOTS
MBB
MARK BEFORE
BREAK
PERIOD TIME
REFRESH
RATE
44 Hz
92 µs
12 µs
-
44 µs
22,7 ms
44,0 Hz
33 Hz
176 µs
24 µs
16 µs
176 µs
31,1 ms
32,1 Hz
22 Hz
220 µs
44 µs
44 µs
440 µs
45,8 ms
21,8 Hz