Version: 1.05, 05.10.18
5
2
Standard Operating Mode - Display
In the standard operating mode the display shows the following
information:
The upper line is static. Below the text "INP", the letters A, B and C
indicate a valid DMX signal present at the respective input.
If no signal is present at one of the three inputs, a line appears at the
same position instead of the character.
In addition, for each input a possibly activated termination switch (for the
120 Ohm line termination) is indicated by an underscore below the
relevant character.
Since the user can also hide the display (configuration menu), there are
two LEDs's on the front for visualizing the main device function for each
input.
The status of each input, where a valid DMX signal is present, is
indicated by slow flashing of the assigned green DMX LED.
If RDM communication (bidirectional) with the line at the output is
currently running via an input, the associated yellow RDM LED flashes.
The merger can only allow one input at a time for RDM communication
with the output line. The device decides which is ultimately the "winner"
with simultaneous RDM telegrams at several inputs based on the time of
RDM detection and a fixed, internal priority sequence (B > C > A).
The currently set MERGE MODE ("HTP" /"LOW" (LoTP) or "LTP") is
shown below the text "MODE", followed by the characters "F" / "M" or "S"
(for FAST / MEDIUM or SLOW) to indicate the speed of the output signal.
INP | MODE
ABC | HTPF
ODE
ABC | F INP |
MODE
ABC | HTPF
Summary of Contents for 4001733
Page 1: ...Major DMX Merger 3in1 User Manual...
Page 16: ...16 Version 1 05 05 10 18...