57
Majestic • QUARTZ32IFTN/L, QUARTZ36IFTN/L, QUARTZ42IFTN/L Installation Manual • 2641-980 Rev. C • 9/20
Note:
All
measurements
in inches.
Combustible Mantels
Figure 10.2 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
Non-Combustible Mantels
Figure 10.3 Minimum Vertical and Maximum Horizontal
Dimensions of Non-Combustibles
C. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as specified. Framing closer than the minimums list-
ed must be constructed entirely of non-combustible
materi
-
als (i.e., steel studs, concrete board, etc.).
Note:
Measurement is taken from top/side of the
opening, NOT the top/side of the fireplace.
Note:
All
measurements
in inches.
TOP OF HOOD OR FIREPLACE OPENING
See Dimension V on Appliance
Dimension Diagram (Figure 3.1).
3
4
5
12
11
10
9
8
7
6
32
CEILING
1
5 6
7 8
9
10
4
12
11
13
3
13
14
15
16
14
15
16
17
TOP OF HOOD OR
FIREPLACE OPENING
See Dimension V on Appliance
Dimension Diagram (Figure 3.1).
12
11
10
9
8
7
6
32
CEILING
8
9
10
12
11
13
13
14
15
16
15
16
17
14
Figure 10.4 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Combustible Mantel Legs or Wall Projections
Non-Combustible Mantel Legs or Wall Projections
UNLIMITED
TOP VIEW
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
3 IN. MIN.
6 IN. MAX.
Figure 10.6 Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Figure 10.5 Combustible Mantel Leg or Wall Projections
(Acceptable on one side of opening)
2-7/8 IN.
MIN
3 FT. MAX.
INTERIOR WALL
TOP VIEW
MANTEL LEG OR WALL PROJECTIONS
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
1/2 IN. MIN
UNLIMITED
TOP VIEW
5-7/8 IN.
MIN.
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
INTERIOR WALL
3 IN.MIN.