WMC Series Woodburning Fireplace

20000583

Framing

Framing can be constructed before or after the fire-
place is set in place, however, most installers build the 
frame before setting the fireplace.
Frame fireplace with 2 x 4 lumber or heavier materials.  
Refer to framing dimensions in Figures 1 and 2 for 
basic fireplace specifications.

NOTE:

  Framing should be positioned to accommo-

date wall covering and fireplace facing material. 

Install Electrical Connection 

CAUTION: ALL WIRING SHALL BE DONE BY A 
QUALIFIED ELECTRICIAN AND SHALL BE IN 
COMPLIANCE WITH ALL LOCAL, CITY AND STATE 
BUILDING CODES.
IMPORTANT:

  To prevent electrical shock, the house 

power must be disabled. This can be accomplished by 
positioning the circuit breaker to off.
The fan kit assembly and model EB1 junction box are 
factory installed.

NOTE:

 Check local building codes to determine if a 

junction box is required at the romex pigtail/house wire 
connection. 

Install Variable Speed Control

The SCVS Variable Speed Control is tested and safe 
when installed in accordance with these instructions. 
Read all instructions before beginning installation. Fol-
low instructions carefully.
The SCVS speed control may be used as an alternate 
wall switch in lieu of the single pole (Listed 1.5 Amp 
120V) switch described in the fan or fireplace installa-
tion instructions.

Installation Instructions

For mounting the speed control, a 2" deep standard 
electrical box should be used. Using wire nuts sup-
plied with the speed control, connect control in series 
with fan motors and line voltage. Refer to Figure 9 for 
wiring diagram.
Mount speed control in electrical box and attach wall 
plate with screws provided. Push on knob so that indi-
cator is in OFF position. (Fig. 10)

Operation

Turn control knob counterclockwise until a click is 
heard for OFF position. To operate fans, turn knob 
clockwise and adjust fan speed as desired.

Green

White

Black

White

FP1212

SCVS wiring

5/23/02   djt

Ground

Ground Screw

Variable Speed Con-

trol (optional)

Wire Nuts

(supplied)

Receptacle

Fireplace 

Junction Box

Ground 

Stud

Wall 

Junction Box 

(not supplied)

Black

FP1212

Fig. 9

  SCVS wiring diagram.

OFF

LOW

FP1213

SCVS 

components

5/24/02   djt

Electrical Box

(not supplied)

Speed Con-

trol

Cover 

Plate

Oval 

Head 

Screw

Plastic 

Knob

Flat 

Head 

Screw

Wire Nut

FP1213

Fig. 10

  Speed control mounting.

Summary of Contents for Royal Collection WMC36

Page 1: ...e in U S Canada Underwriter s Laboratories Report No MH6018 DO NOT DISCARD THIS MANUAL Retain for future use 20000583 4 07 Rev 21 FP583A WMC 12 18 98 WMC Series Woodburning Fireplace Homeowner s Insta...

Page 2: ...manufactured or approved by CFM Corpo ration in combination or assembly with a CFM Corporation replace system notwithstanding any independent testing laboratory or other third party approval of such c...

Page 3: ...Dia 203mm 3 6 9 1 4 m m Fig 2 WMC42 Series speci cations and framing FP592A WMC42 Series Woodburning Fireplace Circulating Model FP590A WMC36 SPECS 1 28 99 djt 1 6 m m 13mm 36 914mm 35 895mm 40 1016m...

Page 4: ...Surround Outlet Grille Damper Control Gas Line Knockout both sides Screen Grate Firebox Metal Safety Strips 1 2 or 3 pieces Inlet Grille Outside Air Cover Plate Electrical Access Gas Line Access both...

Page 5: ...1 0 0 1 0 31 60 0 1 0 1 0 34 65 0 0 2 0 0 37 70 1 1 0 1 1 41 77 0 0 1 1 1 45 83 0 1 2 0 1 47 87 0 0 0 2 1 51 94 0 1 1 1 1 53 98 0 0 3 0 1 56 103 0 1 0 2 1 59 108 0 0 2 1 1 62 113 0 1 3 0 1 64 117 0 0...

Page 6: ...be at least 2 609 mm above the peak of the roof but never less than 3 914 mm in height above the highest point where it passes through the roof 2 If a horizontal distance from the chimney to the peak...

Page 7: ...imates If you live in a cold climate it is not required but highly recommended that you insulate replace enclosure to eliminate cold air penetration as much as possible Insulate base of replace with a...

Page 8: ...ns Read all instructions before beginning installation Fol low instructions carefully The SCVS speed control may be used as an alternate wall switch in lieu of the single pole Listed 1 5 Amp 120V swit...

Page 9: ...oration elbows Use the 30 Offset Elbow table on Page 5 to determine proper offset and parts required Each offset requires two 2 elbows The second elbow is equipped with support straps It is very impor...

Page 10: ...frame for ceiling chimney hole FP551 WF551 BR BC 9 29 97 See Fig 12 See Fig 12 Existing Ceiling Joists Ceiling New Framing Members Chimney Hole Fig 12 Ceiling chimney hole sizes necessary for install...

Page 11: ...e clearly snap together Once sections are snap locked in place it is extremely dif cult to get them apart Make sure the pipe is rmly snapped and locked together as each pipe section is mounted When in...

Page 12: ...raming hole Nail each corner of attic insulation shield to the framing members of the ceiling hole using 8d nails Attic shields are not required at the roof Continue Installing Pipe to Complete Run Co...

Page 13: ...himney sec tions all pipes should extend Installing Top Housing or Termination Follow the installation instructions provided with the chimney termination you have selected Installing Chimney In a Chas...

Page 14: ...oration Wall Shield Model SP40 or a speci cally built wall shield described below The special wall shield design described in Figure 19 is an alternate method of adding protection to side walls and ca...

Page 15: ...rom manufacturer of the material Fac tors are related by the formula K 1 R T given thickness R thermal resistance for a given thickness T K thermal conductivity Noncombustible material with a lower R...

Page 16: ...of listed material per inch material Example of Determining Hearth Extension Equivalents To determine the thickness required for any new mate rial Example for Common Brick T new 5 0 0 458 x 0 50 in 5...

Page 17: ...een the pipe and tube NOTE Gas pipe should not come in contact with any wood structures until it has reached a point at least one 1 inch away from replace side NOTE When installing an ANSI Z21 11 2 ve...

Page 18: ...r replace 7554338 7554338 6 Damper Knob Wood 7536177 7536177 7 Screen Pulls two per replace 5584139 5584139 8 Firebrick Left Side 3041104 3034102 9 Firebrick Back 3030102 3034104 10 Firebrick Right Si...

Page 19: ...n addition such action may void the coverage provided by the owner s insurance Accessories Contact your CFM Corporation distributor or dealer for nishing Mantels available in a wide selection of style...

Page 20: ...le chimney cap used to PLTSK8 SK8 terminate chimney through a chase Includes adapter Flashing not included Chase Top Housing Square chimney cap used to terminate chimney SLTSK8 SK8 through a chase Inc...

Page 21: ...the chimney to combustible framing With 16 center lines Attic Insulation Shield Used to prevent attic insulation from FS2100 HT 3 wall CF 11 contacting the chimney system Canada Chimney Collar Enclos...

Page 22: ...22 WMC Series Woodburning Fireplace 20000583...

Page 23: ...installed in the continental United States the state of Alaska and Canada only if and so long as the Fireplace is installed or serviced by a quali ed installer preferably NFI or WETT Canada certi ed...

Page 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: