background image

6

UVSRCA Vent-Free Fireboxes

20007435

A

B

B

5"

A

1/2"

C

D

T226

framing dimensions

2/04

1/2” Clearance 

not Required at 

This Point

Front View

Side View

   

D

  UVSRC36A 

39

¹⁄₄

” 

44

¹⁄₄

” 

21” 

22”

  UVSRC42A 

45

¹⁄₄

” 

44

¹⁄₄

” 

22” 

32”

T226

Fig. 4

  Framing dimensions.

1"

Min.

T227

gas line install

2/04

Side Refractory

Fireplace 

Outer Wrap

1/2” Gas Pipe

Refractory Cement

Noncombustible Insula-

tion

T227

Fig. 6 

 Gas line installation.

FP1532

Vent free

nailing flanges

10/04

Nailing 

Flanges

FP1532

Fig. 5

  Secure firebox.

Step 5: Gas Piping and Connection

The gas piping must be installed in accordance with 
local codes or, in the absence of local codes, in accor-
dance with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, latest edition.

The normal gas connection is 1/2” NPT, made at the left 
side facing the unit. If a right side connection is desired, 
the connecting pipe must be led at the rear of the fire-
place to terminate at the left hand side for connection to 
the fireplace.
Piping should be tested for leaks prior to final wall 
installation. Test for leaks using soap and water solution 
after completing the connection. DO NOT USE OPEN 
FLAME.

Step 6: Optional Procedure For Cold Climate Instal-
lations

The insulation and sealing of the enclosure around the 
fireplace is very important in cold climates. If the en-
closure is insulated and sealed properly, you can avoid 
future cold air problems. The time taken to install the 
firebox correctly is well worthwhile. The following steps 
are to stop potential cold air problems.

Insulation of the Fireplace Enclosure

When in a chase or an outside wall, the fireplace en-
closure should be insulated like any other wall of your 
home. Insulation should be installed on the outside 
wall(s) and the wall above the fireplace.

Insulate to Seal Under the Fireplace

Insulating under the fireplace is beneficial for installa-
tions on a concrete slab. The fireplace should be placed 
on insulating board. It is important that a hard, rigid 
surface be maintained, so do not use fiberglass insula-
tion for this purpose.

CAUTION:

  WHEN INSTALLING A FIREPLACE IN AN 

INSULATED ENCLOSURE, BE SURE TO MAINTAIN 
ALL MARKED AIR SPACES.

Seal Seams

Seal the seams of the fireplace where the outer wall 
meets the bottom pan and the front face. Also seal 
between the fireplace and finishing materials. Use high 
temperature caulk. Refer to Figure 7 for details of seal-
ing spaces between the fireplace and finishing materi-
als. Note the small amount of insulation installed across 
the top of the fireplace and down the sides as a backing 
for the caulk.

Summary of Contents for FireStage UVSRC36A

Page 1: ...s having jurisdiction i e building inspectors re marshals etc should be consulted before installation to determine the need to obtain a permit When installing the Blower Kit it is necessary to bring t...

Page 2: ...lation 8 UVSRC36A Installation 8 UVSRC42A Installation 8 Install Optional Outside Air Kit 9 Replacement Parts 11 Accessories 12 Servicing 12 Warranty 15 Table of Contents UVSRC36A UVSRC42A Certi ed To...

Page 3: ...8 S 46 53 C G K I F Gas Line Access Rough Opening Height Rough Opening Depth O J 79006 ADCH39 45C SPECS 2 04 S S R Q Rough Opening Width C N 1 2 B D A Fireplace Dimensions Fig 1a UVSRC36A and UVSRC42A...

Page 4: ...n of 1 2 wallboard or plywood ush with the face of the replace Only the header Fig 1 may rest on the standoffs on top of the rebox When the replace is installed over carpeting vinyl tile or any combus...

Page 5: ...to achieve a raised hearth effect This can be done by adding a small platform to achieve the desired height NOTE See pre wiring of Junction Box and Electrical Services on Page 7 Step 2 Install the Fir...

Page 6: ...al lations The insulation and sealing of the enclosure around the replace is very important in cold climates If the en closure is insulated and sealed properly you can avoid future cold air problems T...

Page 7: ...the rebox opening where facing materials such as brick or stone are used on the face of the rebox It acts as a support restop It should be attached to the face of the replace with screws and sealed t...

Page 8: ...ck from the replace and carefully place it to the side to prevent damage Use a at blade screwdriver to gently lift up the front edge of the brick then pull forward to remove Step 4 Locate the blower a...

Page 9: ...to duct termina tion This will provide the least restriction to air ow No more than four 4 90 elbows can be used Duct run may be horizontal vertical inclined or any combina tion of these Fig 12 You ar...

Page 10: ...cap 7 6 00 djt Caulking Duct Ter mination Rain Cap Wall FP1061 Fig 15 Caulk and install duct termination rain cap in place Operating Precautions and Instructions Operation is automatic A slight negati...

Page 11: ...at any time without notice Description UVSRC36A UVSRC42A 1 Firescreen Rod 2 per replace 76397 76397 2 Firescreen w Rings 2 per replace 72301 72301 3 Screen Retainer 4 per replace 62222 62222 4 Back Br...

Page 12: ...sh contact CFM Corporation 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 Accessories Blower Kit BL 4 or FK12 Junction box is provided with replace Heat Reducing Canopy UC36 UVSRC36A UC42 UVSRC42...

Page 13: ...13 UVSRCA Vent Free Fireboxes 20007435...

Page 14: ...14 UVSRCA Vent Free Fireboxes 20007435...

Page 15: ...inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of...

Page 16: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: