MIGE3028-4GF Serial Rack Mounted Industrial Ethernet Switch

- 10 -

Figure2-10 shows the rear panel of the MIGE3028-4GF-4S/M-20T.

Figure2-10 MIGE3028-4GF-4S/M-20T switch front panel

MIGE3028-4GF-8S / M-16T is a schematic view of the rear panel shown in

FIG2-11.

Figure2-11 MIGE3028-4GF-8S/M-16T switch front panel

MIGE3028-4GF -12S/ M-12T is a schematic view of the rear panel shown

in FIG 2-12.

Figure2-12 MIGE3028-4GF-12S/M-12T switch front panel

MIGE3028-4GF-16S / M-8T is a schematic view of the rear panel shown in

FIG.2-13.

Figure2-13 MIGE3028-4GF-16S/M-8T switch front panel

MIGE3028-4GF-24S rear panel/M schematic shown in FIG 2-14.

Figure 2-14 MIGE3028-4GF-24S/M switch front panel

For most industrial applications,19-inch rack mounting is very convenient

for them.Before installation you should check the installation of the
rack,including the following two elements:

If there is enough room to install this product?
If there is a power supply suitable for the work of this product?
When installing, first determine the installation position of the product,

align the hole on the rack with the mounting hole of the switch,and then fix it
with screws. The recommended size is M5×14.

2.2.3. Cable Connection

After the correct installation, the cable can be installed and connected,

mainly including the cable connection of the following interfaces.

Working interface

Summary of Contents for MIGE3028-4GF

Page 1: ...MIGE3028 4GF Serial Rack Mounted Industrial Ethernet Switch User Manual Edition V1 0 Wuhan Maiwe Communication Co Ltd...

Page 2: ...in this manual does not represent for corresponding authorization on these information Our company attempts to ensure the accuracy and applicability for the information provided in this manual howeve...

Page 3: ...ted with each other frequently inspection is needed Please keep the fiber socket and plug clean Do not look directly at the fiber section when the equipment is working Please keep the equipment clean...

Page 4: ...llation and Networking 3 2 1 Hardware Structure 3 2 1 1 System Structure 3 2 1 2 Machine Structure 3 2 2 Hardware Installation 8 2 2 1 Installation Requirements 8 2 2 2 Host Installation 9 2 2 3 Cable...

Page 5: ...ustrial Network Performance Real time broadcast storm suppression Redundant dual power input power failure alarm to meet high availability requirements Storage and forwarding mechanism the switch back...

Page 6: ...rnet switches are as follows Technical indicators IEEE standards 802 3 802 3u 802 3x Exchange mode store and forward Switch bandwidth 12 8Gbps Flow control full duplex flow control half duplex back pr...

Page 7: ...s are EMC protected 2 1 2 Machine Structure The chassis of this series is a 19 inch 1U rack structure The whole machine adopts a six sided fully enclosed structure The left and right side panels of th...

Page 8: ...ort Yellow light Green light Green light Yellow light Green light On Off On Blink Off On Blink Off On Off On Blink Off 100M connection No connection or 10M access Port connection Port has network acti...

Page 9: ...itself to work at the same rate as the other party avoiding full half duplex mismatch the transfer mode will default to half duplex and flow control will be automatically disabled Gigabit Tx ports can...

Page 10: ...ted and pulled and placed in the normal position parallel to the interface Hot extraction step First the SFP plug handle is pulled down and perpendicular to the interface At this time the optical devi...

Page 11: ...rmally open terminal and one normally closed terminal one of the middle is a common terminal the left two bits are normally open terminals and the two right sides are normally closed terminals When th...

Page 12: ...quirements temperature 40 C 85 C relative humidity5 95 no condensation Grounding resistance requirements 5 According to the contract configuration requirements check whether the cable laying is in pla...

Page 13: ...cs can be bundled together Separate the input and output lines It is highly recommended that all equipment lines in the system be labeled when necessary The switch should be connected to the protectio...

Page 14: ...8 4GF 24S rear panel M schematic shown in FIG 2 14 Figure 2 14 MIGE3028 4GF 24S M switch front panel For most industrial applications 19 inch rack mounting is very convenient for them Before installat...

Page 15: ...not look directly at the optical transmission port and the fiber optic terminator end face The steps to connect a pluggable fiber module are as follows Remove and retain the rubber sleeve of LC SC FC...

Page 16: ...ry to prevent the cable from being knotted and the turning point should be minimized and the turning radius should not be too small The lashing should be tight and not too tight When laying on the cab...

Page 17: ...ter 1 Start run or type cmd command Win2000 XP systems cmd WIN98 95 system with command to bring up a console window send ping 192 168 16 221 l 1000 t l Refers to the number of bytes sent by the packe...

Page 18: ...ce is connected to the test computer through a direct connection network cable and sends PING commands to each other Both parties can correctly ping the other party without losing packets At the same...

Page 19: ...e technical support office Product is repaired or replaced 3 1 Internet Service Through the technical support section of Wuhan Maiwe Communication Co Ltd you can get more useful information and tips 3...

Page 20: ...thout notifying the user For the latest information please consult our marketing or technical support staff Model 100M Tx port 100M Fx port Gigabit Fx Tx port MIGE3028 4GF 24T 24 4 MIGE3028 4GF 4S M 2...

Page 21: ...MAIWE COMMUNICATION CO LTD Add Building 2 Area E Phase ii Optical valley core center No 52 Liufang road East Lake Hi tech Development Zone Wuhan China Phone 027 87170215 16 Fax 86 027 87170217 www mai...

Reviews: