MIGE3028-4GF Serial Rack Mounted Industrial Ethernet Switch

II

Safe Use Instruction

This product performance is excellent and reliable in the designed range of use,

but it’s necessary to avoid man-made damage or destroy for the

equipment

.

Read the manual carefully and keep this manual for reference if need

afterwards.

Do not put the device close to the water sources or damp places.

Do not put anything on the power cable, it should be placed out of reach.

To avoid causing fire, do not knot or wrap the cable.

Power connector and other device connectors should be firmly

connected with each other, frequently inspection is needed.

Please keep the fiber socket and plug clean. Do not look directly at the

fiber section when the equipment is working.

Please keep the equipment clean and wipe it with a soft cotton cloth if

necessary.

Please do not repair the equipment by yourself, unless there is clear

instructions in the manual.

Under the following circumstances, please cut off power immediately and
contact us.

Equipment water damage.

The equipment is broken or the casing is broken.

The equipment works abnormally or the performance has completely

changed.

The equipment produces odor, smoke or noise.

Statement: Information requiring explanation in use of the managed software.
Attention: Matters requiring specific attention in the use of the managed
software.

Summary of Contents for MIGE3028-4GF

Page 1: ...MIGE3028 4GF Serial Rack Mounted Industrial Ethernet Switch User Manual Edition V1 0 Wuhan Maiwe Communication Co Ltd...

Page 2: ...in this manual does not represent for corresponding authorization on these information Our company attempts to ensure the accuracy and applicability for the information provided in this manual howeve...

Page 3: ...ted with each other frequently inspection is needed Please keep the fiber socket and plug clean Do not look directly at the fiber section when the equipment is working Please keep the equipment clean...

Page 4: ...llation and Networking 3 2 1 Hardware Structure 3 2 1 1 System Structure 3 2 1 2 Machine Structure 3 2 2 Hardware Installation 8 2 2 1 Installation Requirements 8 2 2 2 Host Installation 9 2 2 3 Cable...

Page 5: ...ustrial Network Performance Real time broadcast storm suppression Redundant dual power input power failure alarm to meet high availability requirements Storage and forwarding mechanism the switch back...

Page 6: ...rnet switches are as follows Technical indicators IEEE standards 802 3 802 3u 802 3x Exchange mode store and forward Switch bandwidth 12 8Gbps Flow control full duplex flow control half duplex back pr...

Page 7: ...s are EMC protected 2 1 2 Machine Structure The chassis of this series is a 19 inch 1U rack structure The whole machine adopts a six sided fully enclosed structure The left and right side panels of th...

Page 8: ...ort Yellow light Green light Green light Yellow light Green light On Off On Blink Off On Blink Off On Off On Blink Off 100M connection No connection or 10M access Port connection Port has network acti...

Page 9: ...itself to work at the same rate as the other party avoiding full half duplex mismatch the transfer mode will default to half duplex and flow control will be automatically disabled Gigabit Tx ports can...

Page 10: ...ted and pulled and placed in the normal position parallel to the interface Hot extraction step First the SFP plug handle is pulled down and perpendicular to the interface At this time the optical devi...

Page 11: ...rmally open terminal and one normally closed terminal one of the middle is a common terminal the left two bits are normally open terminals and the two right sides are normally closed terminals When th...

Page 12: ...quirements temperature 40 C 85 C relative humidity5 95 no condensation Grounding resistance requirements 5 According to the contract configuration requirements check whether the cable laying is in pla...

Page 13: ...cs can be bundled together Separate the input and output lines It is highly recommended that all equipment lines in the system be labeled when necessary The switch should be connected to the protectio...

Page 14: ...8 4GF 24S rear panel M schematic shown in FIG 2 14 Figure 2 14 MIGE3028 4GF 24S M switch front panel For most industrial applications 19 inch rack mounting is very convenient for them Before installat...

Page 15: ...not look directly at the optical transmission port and the fiber optic terminator end face The steps to connect a pluggable fiber module are as follows Remove and retain the rubber sleeve of LC SC FC...

Page 16: ...ry to prevent the cable from being knotted and the turning point should be minimized and the turning radius should not be too small The lashing should be tight and not too tight When laying on the cab...

Page 17: ...ter 1 Start run or type cmd command Win2000 XP systems cmd WIN98 95 system with command to bring up a console window send ping 192 168 16 221 l 1000 t l Refers to the number of bytes sent by the packe...

Page 18: ...ce is connected to the test computer through a direct connection network cable and sends PING commands to each other Both parties can correctly ping the other party without losing packets At the same...

Page 19: ...e technical support office Product is repaired or replaced 3 1 Internet Service Through the technical support section of Wuhan Maiwe Communication Co Ltd you can get more useful information and tips 3...

Page 20: ...thout notifying the user For the latest information please consult our marketing or technical support staff Model 100M Tx port 100M Fx port Gigabit Fx Tx port MIGE3028 4GF 24T 24 4 MIGE3028 4GF 4S M 2...

Page 21: ...MAIWE COMMUNICATION CO LTD Add Building 2 Area E Phase ii Optical valley core center No 52 Liufang road East Lake Hi tech Development Zone Wuhan China Phone 027 87170215 16 Fax 86 027 87170217 www mai...

Reviews: