S3100 Install Manual (For S3100-9/18/26TC (TP)) V5.0
z
Always wear an ESD wrist strap and antistatic uniform when in contact
with circuit boards.
A n t i - i n t e r f e r e n c e
All sources of interference, whether from the device/system itself or the
outside environment, will affect operations in various ways, such as
capacitive coupling, inductive coupling, electromagnetic radiation, common
impedance (including the grounding system) and cables/lines (power
cables, signal lines, and output lines). The following should be noted:
z
Precautions should be taken to prevent power source interruptions;
z
Provide the system with a dedicated grounding, rather than sharing
the grounding with the electronic equipment or lightning protection
devices.
z
Keep away from high power radio transmitters, radar transmitters,
and high frequency strong circuit devices.
z
Provide electromagnetic shielding if necessary.
R a c k C o n f i g u r a t i o n
The dimension of the switch is designed to be mounted on a standard 19’’
rack, DCS-3650’s dimensions are 440mm x 44mm x 229mm (W x H x D).
Please ensure good ventilation for the rack.
z
Ev
ery device in the rack will generate heat during operation, therefore
vent and fans must be provided for an enclosed rack, and devices
should not be stacked closely.
z
When mounting devices in an open rack, care should be taken to
prevent the rack frame from obstructing the switch ventilation
openings. Be sure to check the positioning of the switch after
installation to avoid the aforementioned.
Caution
If a standard 19’’ rack is not available, the switch can be placed on a clean
level desktop, leave a clearance of 10mm around the switch for ventilation,
and do not place anything on top of the switch.
Maipu Confidential & Proprietary Information
Page
20
of
26