The  router  provides  inbuilt  and  highly  efficient  hardware  encryption 

engine. The encrypting data does not occupy bandwidth and CPU of the 

router system realizing that high-speed encryption does not affect data 

forwarding  efficiency.  For  widely-used  IP  private  line,  encrypting  data 

via  WAN  is  the  safest  method  of  ensuring  the  security  of  important 

data. 

 

§

 

Each  Ethernet  port  uses  L2/L3  technology  to  realize  flexible 

support for services 

All  Ethernet interfaces  of  MP2800  support  L2/L3  technology to  realize 

the control for different networking modes and services, avoiding poor 

control capacity caused by using Layer-2 switch and the problem that 

adopting  routers  occupies  lots  of  IP  addresses.  In  this  way,  we  can 

simplify  network  configuration  and  strengthen  management  and 

control capacity of network for services. 

§

 

 

§

 

High-density  Ethernet  port  and  asynchronous  port  to  access 

large-capacity Ethernet devices and traditional terminals 

MP2816 and MP2818 models are configured with 2+24 100M Ethernet 

ports  to  access  network  terminals,  PC  and  video  terminals.  Users  do 

not  need  to  purchase  Ethernet  switches,  saving  network  investment 

and  reducing  faults.  Considering  there  are  some  dumb  terminals  to 

access, MP2800 has extension slots which can be extended to up to 64 

asynchronous  interfaces  to  access  traditional  terminals  and  large-

capacity Ethernet devices in network nodes/branch offices. 

 

§

 

Hierarchical QoS 

The  priorities  of  various  services  can  be  realized  on  specified 

bandwidth of MSTP 100M port. MP2800 supports narrowband lines and 

MSTP/MPLS  broadband  lines.  For  MSTP/MPLS,  the  lines  are  for  100M 

interfaces,  but  in  fact,  the  bandwidth  applied  by  users  is  only  a  part 

such as 2M, 5M, 10M, 20M and 50M. Inconsistency between interface 

bandwidth and practical bandwidth results in traditional QoS becoming 

invalid. S0 MP2800 router adopts hierarchical QoS on Ethernet ports to 

realize  bandwidth  control  first,  and  then  secondary  bandwidth 

allocation  for  different  services.  The  QoS  service  of  MP2800  router 

supports  RSVP,  CAR  and  queue  policies  such  as  FIFO,  PQ,  CQ,  FQ, 

CBWFQ and LLQ to ensure priorities of key services. 

§

 

 

§

 

Supports  MPLS  and  L2TPv3  to  provide  strict  network  area 

division for a single line bearing multiple services 

MP2800 supports MPLS, L2TP and IPsec, which can be used to deploy 

VPN networks from Layer 2 to Layer 3. When branch offices are inter-

connected  by  various  lines,  multiple  services  can  be  born  on  a  single 

physical network to ensure the security and save cost. 

 

§

 

Integrates  routing,  switching,  security,  voice,  transmission, 

storage and 3G 

MP2800  integrates  routing,  switching,  transmission,  security,  local 

storage and 3G. The series leads ways of edge routers - 

Faster, more 

intelligent, more powerful

. The inbuilt intelligent switch, firewall, VPN 

(including MPLS VPN, IPsec VPN and L2TP VPN), VoIP and transmission 

PDF 

文件使用

 "pdfFactory Pro" 

试用版本创建

 (         

www.fineprint.com.cn

Summary of Contents for MP2800 Series

Page 1: ...Install Manual V1 2 Maipu Communication Technology Co Ltd No 16 Jiuxing Avenue Hi Tech Park Chengdu Sichuan Province P R China 610041 Tel 86 28 85148850 85148041 Fax 86 28 85148948 85148139 URL http w...

Page 2: ...lied warranties of merchantability or fitness for any specific purpose Further Maipu reserves the right to revise this document and to make changes from time to time in its content without being oblig...

Page 3: ...ngement appearance Good Fair Average Poor Accessibility Contents index headings numbering Good Fair Average Poor Evaluate this document Editorial Language vocabulary readability clarity technical accu...

Page 4: ...channelized E1 Module E1 Series 17 1 port Non channelized E1 Module 1E1 17 Frequency band MODEM M336 Series 18 11 port 33 6K Frequency band MODEM 1M336 18 ISDN U Series 19 1 port ISDN U Module 1U 19 I...

Page 5: ...Routers Accessories 33 Tools Equipment 33 System Installation 35 Preparations 35 Tools 35 Checking Cabinet 35 Checking Routers Accessories 36 Installing Router 37 Main Control Board Cable Connection...

Page 6: ...industries The router provides many software features such as SNA DLSw VoIP VPN MPLS multicast MAC address binding and access control and bandwidth restriction The series provides backup schemes and...

Page 7: ...e MODEM and ISDN dial backup schemes The fast forwarding engine technology developed by Maipu makes WAN 100M line interface reach wire speed forwarding supporting the extension of WAN line bandwidth t...

Page 8: ...nterfaces to access traditional terminals and large capacity Ethernet devices in network nodes branch offices Hierarchical QoS The priorities of various services can be realized on specified bandwidth...

Page 9: ...tection The router is the first in China to realize SNA DLSw and LLC2 protocols It is compatible with network devices of main manufacturers in the industry Structure MP2800 series routers adopt 19 sta...

Page 10: ...WAN Ethernet 1 100M 10 100M Ethernet interface data rate indicator On 100M Off 10M ACT Ethernet interface data receiving sending indicator LAN Ethernet 0 23 100M 10 100M Ethernet interface data rate...

Page 11: ...r design Users can select different interface cards and the corresponding software modules as desired 1ETE modules are supported only by multi functional slots S0 and S1 The 3G module is supported onl...

Page 12: ...MP2806 42W 10 MP2816 52W 10 MP2818 Functions MP2800 routers support the following protocols and services Protocol Service Description Network protocol WAN supports PPP PPP compression SLIP CSLIP proto...

Page 13: ...ocal configuration via console port Local or remote login via local Telnet Configuration command security isolation function Chinese English prompt and help information Detailed debugging information...

Page 14: ...800 Series Router Install Manual V1 2 Maipu Confidential Proprietary Information Page 14 of 47 NAT RADIUS TACACS IPSEC data encryption AAA 802 1x SNA GRE L2TP IKE PDF pdfFactory Pro www fineprint com...

Page 15: ...speed V 24 V 35 Serial Module 1SAE 1SAE module is used for MP2800 router Its main function is to complete data flow receiving sending and processing For sync port 2 048Mbps in DCE mode and 8 Mbps in D...

Page 16: ...4 V 35 Interface standard working mode DTE DCE DTE DCE EIA TIA 232 Minimum BR bps 1200 1200 300 Maximum BR bps 128K 8M 115 2K Dialup Backup Protocol Service X25 HDLC PPP SLIP FR LAPB HDLC PPP SLIP Cha...

Page 17: ...ributes Description Interface BNC RJ45 cannot be used at the same time Number of interfaces One group for each Interface standard G 703 Supported Protocol PPP X 25 HDLC FR Non channelized E1 Module E1...

Page 18: ...on channelized E1 1E1 attributes Attributes Description Interface BNC RJ45 cannot be used together Number of interfaces One group for each Interface standard G 703 Supported service X 25 FR Supported...

Page 19: ...FF LINE port is used as CONSOLE port Configure router via dialup remote login 1M336 Interface Module Connected Cable 1M336 module connected cable is RJ45 4 5 signal wire or RJ11 telephone line 1M336 I...

Page 20: ...28K 1 port ISDN U module 1U DIP switch DIP switch configuration Mode 1 2 Description Loopback ON Reserved 1U Module Connected Cable 1U module connected cable is RJ45 4 5 signal cable or RJ11 line 1U I...

Page 21: ...ule Connected Cable 1VOP module connected cable is RJ45 4 5 signal cable and RJ11 line 1VOP Interface Attributes 1 port IP phone module 1VOP interface attributes Attributes Description Interface RJ45...

Page 22: ...2VOP interface attributes Attributes Description Interface RJ45 jack two RJ11 plugs Number of interfaces 2 RJ11 Supported protocol H 225 H 245 RTP RTCP G 711 G 723 G 729 1 port Switch IP Phone Module...

Page 23: ...RTP RTCP G 711 G 723 G 729 2 port Switch IP Phone Module 2VOS The 2 port switch IP phone module can access any telephone in IP network through dialup You can easily make a free phone call by using the...

Page 24: ...ule ETE Series 1 port Ethernet Module 1ETE 1 port Ethernet module realizes Ethernet connection 1ETE Module Indicator 1ETE module 1 port Ethernet module 1ETE 1 port switch IP phone module 1ETE indicato...

Page 25: ...T module 1ST indicator Indicator Meaning ACT Activated indicator and it is on when running normally B1 B1 channel indicator and it is on when using channel B1 with the rate of B1 64K or B1 B2 128K B2...

Page 26: ...1ST module 1STA Module Indictor 1STA module 1 port ISDN S T module 1STA 1 port ISDN S T module 1STA indicator Indicator Meaning ACT Activated indicator and it is on when running normally B1 B1 channe...

Page 27: ...8 async serial module 8AX 8AX Module Connected Cable 8AX module connected cable is 8 async serial cable 8AX Interface Attributes 8 async serial module 8AX interface attributes Attributes Description...

Page 28: ...e CDMA2000 3G module and USIM card RM2 3G CDMA V2 Module and Indicators RM2 3G CDMA V2 module The indicators of RM2 3G CDMA V2 module Indicator Color Meaning Off Not power on WWAN Green On Power on Of...

Page 29: ...Off Weak signals 103dBm On Strong signals 55dBm RSSI Green Flash 55dBm Middle low signals 103dBm Off No HSDPA service HSDPA Green On With HSDPA service Off No GSM GPRS service UMTS Green On With GSM...

Page 30: ...nts Do not hot swap interface modules and interface cards of routers Do not hot swap cables Connect the interface cables of routers correctly especially do not connect phone lines including ISDN lines...

Page 31: ...and humidity in computer room Temperature Relevant humidity Long term Short term Long term Short term 15 30 0 40 40 65 10 90 Measuring points of the working temperature and humidity of MP2800 in the...

Page 32: ...l system such as floor material and chassis structure To prevent the damage caused by the static do as follows Ensure proper equipment grounding Maintain dustproof room Keep suitable temperature humid...

Page 33: ...amaged To prevent the damages caused by lightning do as follows Ensure that the protect ground of the chassis is well grounded Ensure that the grounding point of AC power supply jack is well grounded...

Page 34: ...nual V1 2 Maipu Confidential Proprietary Information Page 34 of 47 Anti static equipment Connected cables Cables in the package Equipment HUB or Ethernet switch Configuring terminal can be PC PDF pdfF...

Page 35: ...of 19 inch standard cabinet so they can be installed and fixed normally on 19 inch standard cabinet Before installation reserve enough slot room for installing the device Center distance of the horizo...

Page 36: ...it Check whether the floating nut for fixing the device is installed in the square hole of the cabinet column If not insert the floating nut to the square hole according to the position of the pallet...

Page 37: ...the device faces the operator Use the hands to stabilize the device and keep it horizontal Place the device from the cabinet front to the pallet or bracket carefully and avoid that the device hits th...

Page 38: ...connection and configuration refer to the later chapter Configure the router via the terminal as follows Step 1 Find a character terminal a standard terminal with RS 232 serial or normal PC The latter...

Page 39: ...10 MP2806 42W 10 MP2816 52W 10 MP2818 When connecting power supply use the below suggested power supply jack or MIM PC power supply jack for reliable grounding When laying cables for buildings the gr...

Page 40: ...t as follows Installing MP2800 series modules The steps for installing modules Choose the desired modules and interfaces for the corresponding relationship of modules and slots refer to the interface...

Page 41: ...nected to the router refer to the manual of the device The following table can also help you determine the device type Typical DTE and DCE equipment Device Type Interface Type Typical Device DTE Pin t...

Page 42: ...ce of 1CE1 E1 module Step 2 Connect another side to the corresponding equipment Connect TX to RX equipment Connect RX to TX line Step 3 After power on check LOS status of 1CE1 E1 module Indicator on m...

Page 43: ...ction make sure about the ID on the interface to avoid inserting to other interfaces which causes the damage of modules and router host 1VOS 2VOS Module Interface Cable Connection Inset telephone line...

Page 44: ...8AX Module Interface Cable Connection Inset DB60 plug of 8AX cable to 8AX jack Screw down the fixed knob Connect another side of RJ45 plug to equipment wire During the connection make sure about the...

Page 45: ...ion RJ45 Description Length 1 TX0 1 2 TX0 2 Twisted pair 1 3 RX0 3 6 RX0 6 Twisted pair 2 4 4 5 5 Twisted pair 3 7 7 8 8 Twisted pair 4 2m RJ45 cross cable type 5 twisted pair connection relation RJ45...

Page 46: ...1 CTS 8 2 DSR 6 3 RXD 2 4 GND 5 5 6 TXD 3 7 DTR 4 8 RTS 7 1 9 3m RM2 1E1 RM2 1CE1 Using RJ45 RJ45 Crossover Twisted Pair If RJ45 RJ45 crossover twisted pair is needed when using RJ45 interface of E1...

Page 47: ...MP2800 Series Router Install Manual V1 2 Maipu Confidential Proprietary Information Page 47 of 47 8 6 RJ45 interface cable sequence PDF pdfFactory Pro www fineprint com cn...

Reviews: